Evaluation of Verisyse and Artiflex phakic intraocular lenses during accommodation using Visante optical coherence tomography.

机译:使用Visante光学相干断层扫描在住宿期间对Verisyse和Artiflex晶状体人工晶状体进行评估。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To perform a dynamic study of the relationship between Verisyse (AMO) and Artiflex (Ophtec B.V.) phakic intraocular lenses (pIOLs) and anterior chamber structures during accommodation using optical coherence tomography (OCT) (Visante, Carl Zeiss Meditec, Inc.) SETTING: Institutional practice. METHODS: Eleven myopic patients were randomly selected to have implantation of a Verisyse pIOL in 1 eye and an Artiflex pIOL in the other. Using a 2-dimensional image, dynamic measurements of the relationship between the anterior surface of the pIOL and the corneal endothelium, the posterior surface of the pIOL and the anterior surface of the crystalline lens, and the pupil diameter were performed using Visante OCT. Physiological accommodation was stimulated by adding lenses in 1.00 diopter (D) steps from +1.00 to -7.00 D. RESULTS: Both groups had a significant decrease in pupil diameter (P<.0001, generalized linear model [GLM]) and in the distance between the anterior surface of the pIOL and the corneal endothelium (P<.0001, GLM) with accommodation. There were no statistically significant changes in the distance between the posterior surface of either pIOL and the anterior surface of the crystalline lens (P = .2845, GLM). There were no statistically significant differences between the 2 pIOLs in any measurement (P>.05, GLM). CONCLUSIONS: The results fit with Helmholtz' theory of accommodation as forward movement of the diaphragm iris-crystalline lens was seen. There was a decrease in the distance between the pIOL and corneal endothelium and in the pupil diameter, whereas the distance between both pIOLs and the crystalline lens remained constant throughout the accommodation examination. This suggests that the risk for cataract from intermittent contact between the crystalline lens and IOL from accommodative effort is unlikely.
机译:目的:进行动态研究Verisyse(AMO)和Artiflex(Ophtec BV)有晶状体人工晶状体(pIOLs)与前房结构之间的关系,方法是使用光学相干断层扫描(OCT)(Visante,Carl Zeiss Meditec,Inc.)地点:机构实践。方法:随机选择11例近视患者,其中一只眼睛植入Verisyse pIOL,另一只眼睛植入Artiflex pIOL。使用二维图像,使用Visante OCT动态测量pIOL的前表面和角膜内皮,pIOL的后表面和晶状体的前表面之间的关系以及瞳孔直径。通过从+1.00到-7.00 D的1.00屈光度(D)步距增加镜片来刺激生理适应性。结果:两组的瞳孔直径和距离均显着减小(P <.0001,广义线性模型[GLM])在pIOL的前表面和角膜内皮之间(P <.0001,GLM)进行调节。 pIOL的后表面和晶状体的前表面之间的距离没有统计学上的显着变化(P = .2845,GLM)。在任何测量中,两个pIOL之间均无统计学上的显着差异(P> .05,GLM)。结论:该结果符合Helmholtz的适应性理论,因为可以看到隔膜虹膜晶体的向前运动。 pIOL与角膜内皮之间的距离和瞳孔直径减小,而pIOL与晶状体之间的距离在整个适应性检查中保持恒定。这表明由于调节作用而使晶状体与IOL间断接触而引起白内障的风险不大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号