首页> 外文期刊>Journal of cataract and refractive surgery >Depth of focus in eyes with diffractive bifocal and refractive multifocal intraocular lenses.
【24h】

Depth of focus in eyes with diffractive bifocal and refractive multifocal intraocular lenses.

机译:双折射和折射多焦点人工晶状体在眼睛中的焦深。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To evaluate monocular and binocular depth of focus in eyes with different multifocal intraocular lens (IOLs) systems. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: In this comparative interventional study, binocular implantation of multifocal IOLs was performed in 3 groups. In the first group, 26 eyes of 13 patients received asymmetric Acri.Twin (Acri.Tec) IOLs, a near-weighted 733D in 1 eye and a distance-weighted 737D in the fellow eye. In the second group, 26 eyes of 13 patients received a diffractive 811E IOL (Pharmacia). In the third group, 26 eyes of 13 patients received a refractive Array IOL (AMO). The visual acuity was tested monocularly and binocularly starting at 6 m in 0.50 diopter (D) defocusing steps. RESULTS: Distance visual acuity was best in eyes with the distance-dominated 737D IOL; eyes with the other IOLs had comparable results. Binocular distance visual acuity was comparable between the Acri.Twin group and the 811E group. TheAcri.Twin group had better distance visual acuity than the Array group (P< or =.048). Near visual acuity was best in eyes with the near-weighted 733D, followed by the 737D and the 811E. Patients with Array IOLs had worse visual acuities at reading distance (between 33 cm and 40 cm) (P< or =.001). Patients with diffractive bifocal IOLs had better results than patients with refractive multifocal IOLs at reading distance (P< or =.018). CONCLUSION: The diffractive IOLs performed better than refractive IOLs. Asymmetric-weighted IOLs provided better binocular depth of field.
机译:目的:通过不同的多焦点人工晶状体(IOL)系统评估单眼和双眼的景深。地点:奥地利维也纳医科大学眼科。方法:在这项比较性的干预性研究中,将多焦点人工晶状体的双眼植入分为3组。在第一组中,有13例患者的26只眼接受了不对称Acri.Twin(Acri.Tec)IOL,一只眼中的近重733D和另一只眼中的近重737D。在第二组中,有13例患者的26眼接受了811​​E IOL衍射(Pharmacia)。在第三组中,有13位患者的26只眼睛接受了屈光性人工晶体(AMO)。以0.50屈光度(D)的散焦步骤从6 m开始单眼和双眼测试视力。结果:以远距离为主的737D IOL在眼睛中的远视力最佳。眼睛与其他人工晶体的结果相当。 Acri.Twin组和811E组之间的双眼距离视敏度相当。 Acri.Twin组的远距离视力比Array组更好(P <或= .048)。 733D和737D和811E分别是近权重和近视力。 Array IOL的患者在阅读距离(33 cm至40 cm)处的视力较差(P <或= .001)。在阅读距离上,衍射双焦点IOL的患者比屈光多焦点IOL的患者更好(P <或= .018)。结论:衍射IOL的性能优于折射IOL。不对称加权IOL提供更好的双目景深。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号