PURPOSE: To study the relationship between pupil size and light intensity using the Procyon pupillometer. SETTING: University based clinic. METHODS: In this retrospective study, 20 consecutive patients had pupil size assessment with the Procyon pupillometer under 3 different light conditions--4, 0.4, and 0.04 lux. Correlation was established using the log unit of the light intensity and pupil size. RESULTS: The correlation coefficient for the association between pupil size and log unit of light intensity in all eyes was significant (P<.001). The mean correlation coefficient for the association between pupil size and log unit of light intensity in all patients was 0.968 +/- 0.089 (SD) in the right eye and 0.970 +/- 0.031 in the left eye. CONCLUSION: The linear relationship between the pupil size and the log unit of the light intensity showed a tight correlation in all cases. These results can be useful in the comparing pupil size with pupillometers that work under different light conditions.
机译:目的:使用Procyon瞳孔计来研究瞳孔大小和光强度之间的关系。地点:大学诊所。方法:在这项回顾性研究中,连续20例患者使用Procyon瞳孔计在3种不同的光照条件下(-4、0.4和0.04 lux)进行瞳孔大小评估。使用光强度和瞳孔大小的对数单位建立相关性。结果:所有眼睛的瞳孔大小与光强度的对数单位之间的相关性相关系数均显着(P <.001)。在所有患者中,瞳孔大小与光强度的对数单位之间的关联的平均相关系数在右眼为0.968 +/- 0.089(SD),在左眼为0.970 +/- 0.031。结论:在所有情况下,瞳孔大小和光强度的对数单位之间的线性关系均显示出紧密的相关性。这些结果对于将瞳孔大小与在不同光线条件下工作的瞳孔计进行比较可能很有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号