PURPOSE: To compare the visual outcome and subjective visual symptoms in patients who had implantation of the AcrySof ReSTOR multifocal intraocular lens (IOL) (Alcon Laboratories) with those in patients who received the AcrySof SA60AT monofocal IOL (Alcon Laboratories) in cataract surgery. SETTING: Southend Hospital, Essex, United Kingdom. METHODS: Eighty eyes of 40 patients received the ReSTOR multifocal IOL after cataract extraction. They were closely paired in age, sex, and ocular findings with patients who had monofocal IOL implantation during the same period. The distance and near visual acuities were compared, and patient satisfaction with their vision, visual symptoms, and spectacle dependence was assessed using a standardized questionnaire. RESULTS: There was no significant difference in the mean uncorrected and best corrected distance visual acuities between the groups. An uncorrected distance visual acuity of 20/30 or better was achieved in 93.8% eyes in the multifocal group and 82.5% in the monofocal group and of 20/20 or better in 57.5% and 40.0%, respectively (P .18). Uncorrected near visual acuity was 20/30 or better in 75.0% of eyes in the multifocal group and 3.8% in the monofocal group. Reading glasses were required by 2.5% in the multifocal group and by 92.5% in the monofocal group. Satisfactory uncorrected intermediate distance vision was achieved in 75.0% of eyes in the multifocal group and 87.5% in the monofocal group (P = .089); 85.0% of patients in the multifocal group and 7.5% in the monofocal group never had to wear glasses. Moderate glare was reported by 21.3% in the multifocal group and 7.5% in the monofocal group (P = .008); no patient reported severe glare. In the multifocal group, severe halos and moderate halos occurred in 5.0% of eyes and 33.8% of eyes, respectively. CONCLUSIONS: The AcrySof ReSTOR IOL provided predictably good uncorrected distance and uncorrected near acuities. Spectacle independence was significantly higher with this multifocal IOL, which outweighed the photic symptoms it caused.
机译:目的:比较在白内障手术中植入AcrySof ReSTOR多焦点人工晶状体(IOL)(Alcon Laboratories)与接受AcrySof SA60AT单焦点IOL(Alcon Laboratories)的患者的视觉结果和主观视觉症状。地点:英国埃塞克斯郡绍森德医院。方法:40例患者的80只眼在白内障摘除术后接受了ReSTOR多焦点人工晶体。他们在年龄,性别和眼部检查结果上与同期同期单焦点人工晶状体植入的患者密切相关。比较了远视力和近视力,并使用标准化问卷对患者对其视力,视觉症状和眼镜依赖性的满意度进行了评估。结果:两组之间的平均未矫正视力和最佳矫正远视力没有显着差异。在多焦点组中,有93.8%的眼睛和在单焦点组中有82.5%的未矫正远距离视力达到20/30或更高,在单焦点组中分别达到了20/20或更高的远视力(P .18)。在多焦点组中,未矫正的近视敏度为75.0%的眼睛为20/30或更好,而单焦点组为3.8%。多焦点组需要老花镜2.5%,单焦点组需要92.5%。在多焦点组中,有75.0%的眼睛获得了满意的未经矫正的中距离视力,在单焦点组中,则达到了87.5%(P = .089);多焦点组中有85.0%的患者和单焦点组中有7.5%的患者从未戴眼镜。多焦点组中度眩光的发生率为21.3%,单焦点组中为7.5%(P = .008);没有患者报告严重眩光。在多焦点组中,严重光晕和中度光晕分别发生在5.0%的眼睛和33.8%的眼睛。结论:AcrySof ReSTOR IOL可提供良好的未矫正距离和未矫正近视力。这种多焦点IOL的眼镜独立性明显更高,它超过了它引起的光亮症状。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号