首页> 外文期刊>Journal of cataract and refractive surgery >Visual performance of aspherical and spherical intraocular lenses: intraindividual comparison of visual acuity, contrast sensitivity, and higher-order aberrations.
【24h】

Visual performance of aspherical and spherical intraocular lenses: intraindividual comparison of visual acuity, contrast sensitivity, and higher-order aberrations.

机译:非球面和球面人工晶状体的视觉性能:视觉敏锐度,对比度灵敏度和高阶像差的个性化比较。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To intraindividually compare visual performance in terms of photopic high-contrast visual acuity (HCVA), mesopic HCVA, mesopic low-contrast visual acuity (LCVA), and contrast sensitivity (CS) in patients after implantation of either an aspherical or a spherical intraocular lens (IOL). SETTING: Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS: Forty eyes of 20 patients were randomized to implantation of an aspherical IOL (Tecnis Z9000, AMO) in 1 eye and a spherical IOL (Sensar AR40e, AMO) in the other eye. Three to 4 months postoperatively, photopic HCVA (270 cd/m(2)) was measured with the observer-independent Frankfurt-Freiburg Contrast and Acuity Test System (FF-CATS) and high-mesopic HCVA and LCVA (8 cd/m(2)) were measured with Early Treatment Diabetic Retinopathy Study charts. CS was assessed with the FF-CATS under photopic (167 cd/m(2)), high-mesopic (1.67 cd/m(2)), and low-mesopic (0.167 cd/m(2)) luminance conditions with and without glare. For each individual eye, higher-order wavefront aberrations were reconstructed for a physiological mesopic pupil diameter. Intraindividual differences (Delta(i)) in visual acuity, contrast sensitivity, and higher-order aberrations (HOAs) were calculated, and the influence of age and Delta(i) HOA on Delta(i) contrast sensitivity (logCS) under high-mesopic conditions was investigated using multiple regression analysis. RESULTS: There were no statistically significant differences between the Tecnis IOL and the Sensar IOL in visual acuity measurements or contrast sensitivity measurements. For physiological mesopic pupil diameter, primary spherical aberration (Z(4)(0)) was significantly lower in the Tecnis group (P<.001). For all parameters studied except Z(4)(0), the Delta(i) values were distributed around zero. Multiple regression analysis showed only a partial influence of Delta(i) Z(4)(0) on Delta(i) logCS (adjusted R(2) = 0.49) but did not show any influence of age, coma-like aberration, or residual HOA. CONCLUSIONS: Although Z(4)(0) was significantly lower in the eyes with the aspherical IOL, no statistically significant differences were found between aspherical and spherical IOLs in LCVA, HCVA, and contrast sensitivity. Statistical analysis of intraindividual contrast sensitivity differences showed that in most patients, this Z(4)(0) difference was too low to have an effect on contrast sensitivity.
机译:目的:在非球面或球面植入后,分别就患者的视力高对比视力(HCVA),中视HCVA,中视低对比视力(LCVA)和对比敏感度(CS)分别比较视觉表现人工晶状体(IOL)。地点:德国美因河畔约翰·沃尔夫冈·歌德大学眼科。方法:将20例患者的40只眼随机分为一只眼植入非球面IOL(Tecnis Z9000,AMO),另一只眼植入球形IOL(Sensar AR40e,AMO)。术后3至4个月,使用独立于观察者的法兰克福-弗赖堡对比和敏锐度测试系统(FF-CATS)和高近视HCVA和LCVA(8 cd / m( 2))用早期糖尿病视网膜病变研究图表进行测量。 CS用FF-CATS在明视(167 cd / m(2)),高近视(1.67 cd / m(2))和低近视(0.167 cd / m(2))的亮度条件下进行评估,并且没有眩光。对于每只眼睛,针对生理性中视瞳孔直径重建了更高阶的波前像差。计算了视力,对比敏感度和高阶像差(HOA)的个体差异(Delta(i)),并且在高视场下年龄和Delta(i)HOA对Delta(i)对比敏感度(logCS)的影响使用多元回归分析研究了介观条件。结果:Tecnis IOL和Sensar IOL在视力测量或对比敏感度测量上没有统计学上的显着差异。对于生理性中视瞳孔直径,Tecnis组的初级球面像差(Z(4)(0))显着较低(P <.001)。对于除Z(4)(0)以外的所有已研究参数,Delta(i)值均分布在零附近。多元回归分析显示,Delta(i)Z(4)(0)仅对Delta(i)logCS产生部分影响(调整后的R(2)= 0.49),但未显示年龄,彗形像差或年龄的任何影响。剩余HOA。结论:尽管非球面IOL的眼睛中Z(4)(0)显着降低,但LCVA,HCVA和对比敏感度方面,非球面IOL和球面IOL差异均无统计学意义。个体内对比敏感度差异的统计分析表明,在大多数患者中,此Z(4)(0)差异过低,无法对对比敏感度产生影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号