Visual and refractive status at different focal distances after implantation of the ReSTOR multifocal intraocular lens.

机译:植入ReSTOR多焦点人工晶状体后,在不同焦距下的视觉和屈光状态。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To evaluate the visual acuity and determine the refraction in emmetropic pseudophakic eyes at different focal distances after implantation of the AcrySof SA 60D3 ReSTOR multifocal intraocular lens (IOL) (Alcon Laboratories). SETTING: Private clinical practice. METHODS: Thirty-seven eyes of 20 patients received the ReSTOR IOL. Visual acuity was measured at several distances, and best distance corrected, best intermediate corrected (60 cm), and best near corrected (33 cm) visual acuities were determined 3 months after surgery. Subjective outcomes were assessed by a questionnaire. RESULTS: Postoperatively, 36 of 37 eyes (97.3%) were within +/-1.00 diopter (D) of the manifest refraction spherical equivalent and cylinder. Monocularly, the mean best distance corrected, best distance corrected intermediate, and best distance corrected near visual acuities were 20/20, 20/46, and 20/23, respectively. The best distance corrected acuities at 40, 50, 60, and 70 cm were significantly worse than the best distance corrected and best distance corrected near acuities (P<.05). On the questionnaire, all patients noted intermediate blur, but 75% had little or no difficulty seeing and were bothered by the blur occasionally or never. The mean additional add to best distance correction for best intermediate corrected visual acuity was +1.20 diopters (D) +/- 0.27 D or -1.68 +/- 0.24 D and for best near corrected visual acuity, -0.26 +/- 0.24 D. CONCLUSIONS: Implantation of the ReSTOR IOL offered excellent visual acuity at distance and near distance and functional visual acuity in the intermediate range. For patients who need excellent vision at intermediate range, leaving 1 eye with distance myopia or hyperopia to compensate for intermediate vision may provide consistent good binocular vision over the full range in cases of bilateral implantation.
机译:目的:评估在植入AcrySof SA 60D3 ReSTOR多焦点人工晶状体(IOL)(Alcon Laboratories)后,在不同焦距下的屈光性假晶状体眼的视力并确定屈光度。地点:私人临床实践。方法:20例患者的37只眼接受了ReSTOR IOL。在数个距离处测量视敏度,并在手术后3个月确定最佳距离矫正,最佳中间矫正(60 cm)和最佳近视矫正(33 cm)。主观结果通过问卷进行评估。结果:术后37只眼中有36只(97.3%)在明显屈光度当量球镜和圆柱度的+/- 1.00屈光度(D)以内。单眼而言,校正后的最佳平均距离,校正中间的最佳距离和校正近视力的最佳距离分别为20 / 20、20 / 46和20/23。最佳距离校正后视力在40、50、60和70 cm处明显差于最佳距离校正后和最佳距离校正后近视力(P <.05)。在调查表中,所有患者均注意到中度模糊,但75%的患者几乎看不见或没有困难,偶尔或从未被模糊困扰。为获得最佳中间矫正视力,最佳距离矫正的平均附加值是+1.20屈光度(D)+/- 0.27 D或-1.68 +/- 0.24 D,而对于最佳近视矫正视力则为-0.26 +/- 0.24D。结论:ReSTOR IOL的植入在远距离和近距离提供了出色的视敏度,在中等范围内提供了功能性视敏度。对于需要在中间范围内获得出色视力的患者,在双侧植入的情况下,留给一只眼睛远距离近视或远视以补偿中间视力可能会在整个范围内提供一致的良好双眼视力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号