首页> 外文期刊>Journal of cataract and refractive surgery >Ocular aberrations after cataract surgery with hydrophobic and hydrophilic acrylic intraocular lenses: comparative study.
【24h】

Ocular aberrations after cataract surgery with hydrophobic and hydrophilic acrylic intraocular lenses: comparative study.

机译:白内障手术后使用疏水性和亲水性丙烯酸人工晶状体的眼像差:对比研究。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To compare tilt and some higher-order aberrations (HOAs) in patients who had cataract surgery and implantation of 2 types of acrylic intraocular lens (IOL), the hydrophobic MA60AC (Alcon) or the hydrophilic XLSTABI (Ioltech). SETTING: Fondation Ophtalmologique Adolphe de Rothschild, Department of Pr Hoang-Xuan, Paris, France. METHODS: Sixty eyes were included in this study. Eyes in group 1 (n = 30) received the acrylic hydrophobic MA60AC IOL, and eyes in group 2 (n = 30) received the acrylic hydrophilic XLSTABI IOL. Optical aberrations were measured with Nidek OPD-Scan at least 1 month after cataract surgery for a 6.0 mm pupil diameter using a 6th-order Zernike polynomials decomposition. RESULTS: In group 1, the mean root-mean-square (RMS) coefficient for the total higher aberration was 0.86 microm +/- 0.38 (SD). The mean RMS of the tilt, coma, trefoil, tetrafoil, spherical aberration, and secondary astigmatism was 0.81 +/- 0.45 microm, 0.38 +/- 0.30 microm, 0.55 +/- 0.18 microm, 0.13 +/- 0.23microm, 0.30 +/- 0.13 microm, and 0.17 +/- 0.21 microm, respectively. In group 2, the mean RMS coefficient for the total higher aberration was 0.72 +/- 0.31 microm. The mean RMS of the tilt, coma, trefoil, tetrafoil, spherical aberration, and secondary astigmatism was 0.55 +/- 0.30 microm, 0.24 +/- 0.19 microm, 0.50 +/- 0.23 microm, 0.07 +/- 0.22 microm, 0.32 +/- 0.13 microm, and 0.14 +/- 0.14 microm, respectively. There was a statistical difference in aberrations between the 2 groups for the tilt and the coma aberrations (P<.05). There were more aberrations in the MA60AC IOL group. CONCLUSIONS: The design of the IOL influenced ocular aberrations after cataract surgery. There were more tilt and coma aberrations in the MA60AC IOL group.
机译:目的:比较白内障手术和植入两种类型的丙烯酸类人工晶状体(IOL),疏水性MA60AC(Alcon)或亲水性XLSTABI(Ioltech)的患者的倾斜度和一些高阶像差(HOA)。地点:法国巴黎黄晃轩系眼科学基金会阿道夫·德·罗斯柴尔德。方法:60只眼睛被包括在这项研究中。第1组(n = 30)的眼睛接受丙烯酸疏水性MA60AC IOL,第2组(n = 30)的眼睛接受丙烯酸亲水性XLSTABI IOL。白内障手术后至少1个月,使用6阶Zernike多项式分解,通过Nidek OPD-Scan测量光学像差,瞳孔直径为6.0 mm。结果:在第1组中,总较高像差的平均均方根(RMS)系数为0.86微米+/- 0.38(SD)。倾斜,昏迷,三叶形,四翼形,球差和继发像散的平均RMS为0.81 +/- 0.45微米,0.38 +/- 0.30微米,0.55 +/- 0.18微米,0.13 +/- 0.23微米,0.30 +分别为0.13微米和0.17 +/- 0.21微米。在第2组中,总较高像差的平均RMS系数为0.72 +/- 0.31微米。倾斜,昏迷,三叶形,四翼形,球差和继发像散的平均RMS为0.55 +/- 0.30微米,0.24 +/- 0.19微米,0.50 +/- 0.23微米,0.07 +/- 0.22微米,0.32 +分别为0.13微米和0.14 +/- 0.14微米。倾斜和彗形像差的两组之间的像差有统计学差异(P <.05)。 MA60AC IOL组中的像差更多。结论:人工晶体的设计影响了白内障手术后的眼像差。 MA60AC IOL组中存在更多的倾斜和彗形像差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号