PURPOSE: To compare differences in high-order aberrations (HOAs) between 2 intraocular lens (IOL) optical designs. SETTING: Department of Ophthalmology, Nara Medical University, Nara, Japan. METHOD: Sixty eyes that had uncomplicated phacoemulsification and IOL implantation were assigned to 1 of 2 groups based on the type of IOL optical design: more posteriorly curved biconvex shape (AcrySof MA30BA, Alcon) (n=30 eyes) or more anteriorly curved biconvex shape (AcrySof MA30AC) (n=30 eyes). All patients had best corrected visual acuity better than 20/25. High-order aberrations were measured using a Hartmann-Shack aberrometer at 4.0 mm and 6.0 mm wavefront aperture diameters. RESULTS: At 4.0 mm aperture diameters, there were no differences between the 2 groups in HOAs (P>.05, Mann-Whitney U test) in the cornea and the whole eye. At 6.0 mm aperture diameters, MA30AC eyes had a smaller amount of spherical-like aberrations (P=.043) than MA30BA eyes; however, there were no significant differences between the 2 groups in coma-like aberrations and total aberrations in the whole eye (P>.05). At 6.0 mm aperture diameters, there were no differences between the 2 groups HOAs in the cornea. (P>.05). CONCLUSION: The optical design of the spherical IOL influenced the spherical-like aberrations in the whole eye. This may reduce retinal image quality.
机译:目的:比较两种人工晶状体(IOL)光学设计之间的高阶像差(HOA)的差异。地点:日本奈良奈良医科大学眼科。方法:根据IOL光学设计的类型,将60例不复杂的超声乳化和IOL植入术的眼睛分为2组,其中1组为后弯双凸形状(AcrySof MA30BA,Alcon)(n = 30眼)或前弯双凸形状(AcrySof MA30AC)(n = 30眼)。所有患者的最佳矫正视力均优于20/25。使用Hartmann-Shack像差仪在4.0 mm和6.0 mm的波前孔径直径下测量高阶像差。结果:在孔径为4.0 mm的情况下,两组角膜和全眼HOA的两组之间无差异(P> .05,Mann-Whitney U检验)。在孔径为6.0 mm的情况下,MA30AC眼睛的球状像差(P = .043)比MA30BA眼睛小;然而,两组在整个眼中的彗形像差和总像差之间没有显着差异(P> .05)。在孔径为6.0 mm时,角膜的两组HOA之间没有差异。 (P> .05)。结论:球面人工晶状体的光学设计影响了整个眼睛的球状像差。这可能会降低视网膜图像质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号