PURPOSE: To evaluate the performance of a new microsuction ring during laser in situ keratomileusis (LASIK) in eyes with narrow palpebral apertures. SETTING: Singapore National Eye Centre, Singapore, Republic of Singapore. METHODS: Laser in situ keratomileusis was performed sequentially in both eyes of 33 Chinese patients. A randomization table was used to determine the control and test eyes. A standard suction ring (20.3 mm diameter) was used in control eyes, and a microsuction ring (19.0 mm diameter) was used in test eyes. Corneal flaps were created using the Hansatome microkeratome (Baush & Lomb). The following ring performance parameters were evaluated: flap diameter deviation (actual minus nominal flap diameter), ease of suction ring application, adequacy of suction, and overall microkeratome performance. Parameters 2 to 4 were rated by the surgeons using a subjective 1 to 100 scale. RESULTS: The mean flap diameter deviation was 0.45 mm in the control eyes and 0.22 mm in the study eyes; the mean difference was 0.23 mm (95% confidence interval, 0.39-0.07) (P<.001). For ease of application, the mean score of the microsuction ring was 100 and of the standard suction ring, 89.9. For adequacy of suction, the mean score of the microsuction ring was 99.7 and of the standard suction ring score, 98.2 (P = .13). The mean overall microkeratome performance score using the microsuction ring was 99.4 and using the standard suction ring, 94.6 (P = .011). CONCLUSION: The Hansatome microsuction ring was easy to apply during LASIK in eyes with narrow palpebral apertures, and there appeared to be no compromise of ring performance and safety.
机译:目的:评估在具有狭窄睑裂的眼中进行激光原位角膜磨镶术(LASIK)期间新的微抽吸环的性能。地点:新加坡共和国新加坡国家眼科中心。方法:对33例中国患者的双眼依次进行激光原位角膜磨镶术。使用随机表确定对照眼和测试眼。在对照眼中使用标准的抽吸环(直径20.3毫米),在试验眼中使用微抽吸环(直径19.0毫米)。使用Hansatome微型角膜刀(Baush&Lomb)制作角膜瓣。评估以下环性能参数:瓣直径偏差(实际值减去名义瓣直径),抽吸环的易用性,抽吸的充分性以及整个微型角膜刀的性能。外科医生使用主观1到100量表对参数2到4进行评分。结果:对照眼的平均皮瓣直径偏差为0.45 mm,研究眼的平均皮瓣直径偏差为0.22 mm。平均差异为0.23毫米(95%置信区间为0.39-0.07)(P <.001)。为了便于使用,微吸环的平均评分为100,标准吸环的平均评分为89.9。为了获得足够的抽吸力,微抽吸环的平均评分为99.7,标准抽吸环的评分为98.2(P = .13)。使用微抽吸环的平均总体微型角膜刀性能得分为99.4,使用标准抽吸环的平均总体角膜刀性能得分为94.6(P = .011)。结论:Hansatome微型抽吸环在LASIK手术期间易于在睑裂孔狭窄的眼睛中使用,并且似乎没有损害环的性能和安全性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号