首页> 外文期刊>Journal of cataract and refractive surgery >Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery.
【24h】

Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery.

机译:与白内障手术前的光学生物测定法相比,操作员经验对超声生物测定法性能的影响。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

To compare measurements performed with the IOLMaster (Carl Zeiss, Meditec AG) with those obtained by applanation ultrasound (US) and manual keratometry and to evaluate the effect of operator experience on US biometry.Department of Ophthalmology, University of Vienna, Vienna, Austria.The axial length (696 eyes) and anterior chamber depth (ACD) (462 eyes) were measured in 377 patients with cataract using the IOLMaster and applanation US. To assess the effect of operator experience on the biometric results, the operators were divided into 2 groups: experienced and less experienced in performing US biometry. The difference in measurements between the methods and the variability of the difference were compared between the 2 groups.Applanation US measured axial length and ACD shorter than the IOLMaster; the mean numerical difference was 0.13 mm and 0.19 mm, respectively (P<.01). For axial length, the absolute difference was smaller with experienced operators than with less experienced operators (0.15 mm versus 0.22 mm) (P<.01). For ACD, experienced operators obtained a smaller difference between measurement techniques (0.21 mm versus 0.29 mm; P<.05).Experienced US operators had less difference and lower variability in the difference between applanation US and IOLMaster readings for axial length and ACD measurements. The noncontact optical method, which is essentially operator independent, gave significantly more reliable biometry before cataract surgery, especially in the case of less experienced operators.
机译:将IOLMaster(卡尔蔡司,Meditec AG)进行的测量与压平超声(US)和手动角膜测量法进行的测量进行比较,并评估操作员经验对美国生物统计学的影响。奥地利维也纳大学眼科使用IOLMaster和压平US测量377例白内障患者的眼轴长度(696眼)和前房深度(ACD)(462眼)。为了评估操作员经验对生物特征识别结果的影响,将操作员分为两组:经验丰富的人员和经验较少的执行美国生物特征识别的人员。比较两组方法的测量差异和差异的变异性。压平US测量的轴向长度和ACD短于IOLMaster;平均数值差分别为0.13 mm和0.19 mm(P <.01)。对于轴向长度,有经验的操作者的绝对差小于没有经验的操作者(0.15毫米对0.22毫米)(P <.01)。对于ACD,经验丰富的操作员在测量技术之间的差异较小(0.21 mm对0.29 mm; P <.05)。非接触式光学方法本质上与操作者无关,在白内障手术之前,尤其是在经验较少的操作者的情况下,其生物统计学显着提高了可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号