首页> 外文期刊>Journal of cataract and refractive surgery >Effect of contact lens wear on central corneal thickness measurements.
【24h】

Effect of contact lens wear on central corneal thickness measurements.

机译:隐形眼镜佩戴对中央角膜厚度测量的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To compare central corneal thickness measurements as a function of contact lens wear in patients presenting for refractive surgery. SETTING: Gimbel Eye Centre, Saskatoon, Saskatchewan, Canada. METHODS: A retrospective study of charts yielded 634 eyes meeting the inclusion criterion. Pachymetry measurements of spectacle-wearing control eyes were compared to those of full-time soft contact lens wearers and rigid gas-permeable contact lens wearers. All measurements were taken with the DGH ultrasonic pachymeter by a single observer. RESULTS: Soft contact lens wearers had a mean reduction in corneal thickness measurements of 22 micrometers compared to the control population (P =.00001). Rigid gas-permeable lens wearers had a reduction of 24 micrometers compared to the control population (P =.00001). CONCLUSION: There was a clinically significant reduction in corneal thickness measurements associated with full-time contact lens wear.
机译:目的:比较屈光手术患者中央角膜厚度测量值与隐形眼镜佩戴量的关系。地点:加拿大萨斯喀彻温省萨斯卡通市的金贝尔眼科中心。方法:对图表进行回顾性研究,得出634眼符合纳入标准。将配戴眼镜的对照眼睛的瞳距测量结果与全职软性隐形眼镜佩戴者和刚性透气性隐形眼镜佩戴者进行了测角测量。所有测量均由DGH超声波测厚仪由一名观察员进行。结果:与对照组相比,软隐形眼镜佩戴者的角膜厚度测量值平均减少了22微米(P = .00001)。与对照组相比,刚性透气镜片的佩戴者减少了24微米(P = .00001)。结论:与全时隐形眼镜佩戴有关的角膜厚度测量值在临床上显着减少。