首页> 外文期刊>Journal of cataract and refractive surgery >Corneal tissue ablation depth and the Munnerlyn formula.
【24h】

Corneal tissue ablation depth and the Munnerlyn formula.

机译:角膜组织消融深度和Munnerlyn公式。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

To determine whether the error in ablation depth produced by approximations inherent in the Munnerlyn formula are clinically significant when estimating residual corneal stromal depth for the evaluation before refractive surgery.Department of Ophthalmology, University of Texas Medical Branch, Galveston, Texas, USA.Using identical geometric assumptions, the exact ablation depth was calculated and compared to the approximate ablation depth predicted by the Munnerlyn formula. An adjustment factor was then derived for large optical zones and corrections.The exact ablation depth is always larger than the ablation depth predicted by Munnerlyn's formula. Analysis found the error in ablation depth varied as the fourth power of the optical zone and linearly with correction. The initial corneal radius had little effect on the difference. The ablation depth could be reasonably approximated by adding an adjustment factor for large optical zones and refractive corrections.In patients with large optical zones, it may be preferable to calculate tissue ablation depth using the exact formula. Alternately, the Munnerlyn formula can be used to calculate ablation depth and then an adjustment factor can be added.
机译:为了确定屈光手术前评估残余角膜基质深度时,Munnerlyn公式固有的近似值所产生的消融深度误差是否在临床上具有显着意义。美国德克萨斯州加尔维斯顿市德克萨斯大学医学分校眼科根据几何假设,计算出精确的烧蚀深度,并将其与Munnerlyn公式预测的近似烧蚀深度进行比较。然后得出大光学区域和校正的调整因子。精确的烧蚀深度始终大于Munnerlyn公式预测的烧蚀深度。分析发现,烧蚀深度的误差随光学区域的四次方变化,并且随着校正呈线性变化。初始角膜半径对差异的影响很小。消融深度可通过增加大光学区域的调整因子和屈光矫正来合理地估算。在大光学区域的患者中,最好使用精确公式计算组织消融深度。或者,可以使用Munnerlyn公式计算消融深度,然后可以添加调整因子。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号