首页> 外文期刊>Journal of cataract and refractive surgery >Accuracy and predictability of the compensatory function of Orbscan II in intraocular pressure measurements after laser in situ keratomileusis.
【24h】

Accuracy and predictability of the compensatory function of Orbscan II in intraocular pressure measurements after laser in situ keratomileusis.

机译:激光原位角膜磨镶术后眼压测量中Orbscan II补偿功能的准确性和可预测性。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To evaluate the usefulness of the compensatory function of Orbscan II (Orbtek, Bausch & Lomb) for measuring postoperative intraoperative pressure (IOP) in laser in situ keratomileusis (LASIK) patients. SETTING: Department of Ophthalmology, Ilsan Paik Hospital, Inje University, Ilsan, Korea. METHODS: Two hundred ten patients had LASIK using the Hansatome microkeratome (Bausch & Lomb) and the MEL 70 G-scan laser (Aesclepion-Meditec) and were examined retrospectively. The patients included in the study were divided into 2 groups: Group 1, 123 eyes with less than -6.0 diopters (D) of myopia; Group 2, 60 eyes with more than -6.0 D of myopia. The IOP was measured preoperatively and 2 and 4 weeks after LASIK using a noncontact tonometer (NCT CT-60, Topcon). The results were corrected with the Orbscan II program. RESULTS: The mean IOPs in Group 1 were 16.35 mm Hg +/- 2.90 (SD) preoperatively, 10.80 +/- 2.21 mm Hg at 2 weeks, and 10.63 +/- 2.28 mm Hg at 4 weeks. After compensation with Orbscan II, the 2-week and 4-week values were 16.81 +/- 3.14 mm Hg and 16.68 +/- 3.22 mm Hg, respectively. The mean IOPs in Group 2 were 17.63 +/- 2.93 mm Hg, 10.07 +/-1.55 mm Hg, and 10.43 +/- 1.84 mm Hg, respectively; after compensation, they were 18.40 +/- 4.09 mm Hg and 18.05 +/- 4.09 mm Hg, respectively. After compensation with Orbscan II, there were no statistically significant differences between the preoperative and postoperative IOPs. CONCLUSIONS: Orbscan II may help predict actual IOP values after LASIK and avoid the misinterpretation of high IOPs as normal IOPs.
机译:目的:评估Orbscan II(Orbtek,Bausch&Lomb)的代偿功能在激光原位角膜磨镶术(LASIK)患者中测量术后术中压力(IOP)的有用性。单位:韩国一山仁济大学一山白医院眼科。方法:使用Hansatome微型角膜刀(Bausch&Lomb)和MEL 70 G扫描激光(Aesclepion-Meditec)对211例LASIK患者进行回顾性检查。纳入研究的患者分为2组:第1组,123眼近视度数小于-6.0的近视眼;第2组,近视超过-6.0 D的60眼。术前和LASIK术后2周和4周使用非接触式眼压计(NCT CT-60,Topcon)测量眼压。结果通过Orbscan II程序进行了校正。结果:第1组的平均眼压在术前为16.35 mm Hg +/- 2.90(SD),第2周为10.80 +/- 2.21 mm Hg,第4周为10.63 +/- 2.28 mm Hg。用Orbscan II补偿后,2周和4周的值分别为16.81 +/- 3.14 mm Hg和16.68 +/- 3.22 mm Hg。第2组的平均眼压分别为17.63 +/- 2.93 mm Hg,10.07 +/- 1.55 mm Hg和10.43 +/- 1.84 mm Hg;补偿后,它们分别为18.40 +/- 4.09毫米汞柱和18.05 +/- 4.09毫米汞柱。用Orbscan II补偿后,术前和术后IOP之间无统计学差异。结论:Orbscan II可能有助于预测LASIK术后的实际IOP值,并避免将高IOP误解为正常IOP。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号