...
首页> 外文期刊>Journal of cataract and refractive surgery >Reduction in corneal haze and apoptosis by amniotic membrane matrix in excimer laser photoablation in rabbits.
【24h】

Reduction in corneal haze and apoptosis by amniotic membrane matrix in excimer laser photoablation in rabbits.

机译:准分子激光光切除兔中的羊膜基质可减少角膜混浊和凋亡。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To determine whether preserved human amniotic membrane can reduce corneal haze and keratocyte apoptosis induced by excimer laser photoablation in rabbit corneas. METHODS: Excimer photoablation was performed bilaterally in 30 rabbits with a 6.0 mm ablation zone and 120 microm depth using the VISX Star laser with the phototherapeutic keratectomy (PTK) mode. One eye was randomly covered by preserved human amniotic membrane secured with 4 interrupted 10-0 nylon sutures, and the other eye served as the control. The amniotic membranes were removed at 1 week, and corneal haze was graded with slitlamp biomicroscopy by 3 masked corneal specialists biweekly for the ensuing 12 weeks until the rabbits were killed. Another 18 rabbits were divided into 4 subgroups and received PTK alone, PTK with membrane, PTK with sham sutures, or PTK with tarsorrhaphy. All eyes were studied histologically, and 3 eyes in each group were studied by in situ terminal deoxynucleotidyl transferase deoxy-UTP-nick end labeling assay at 1, 3, and 7 days and 12 weeks, respectively. RESULTS: A consistent grading of differences in corneal haze scoring between the control corneas and the amniotic-membrane-covered corneas was noted among the 3 masked observers. Organized reticular post-PTK corneal haze peaked at 7 weeks in both groups, and the corneal haze score in the amniotic-membrane-covered group was significantly less than in the control group from 7 to 12 weeks (all P < .001). Compared to the control corneas, the amniotic-membrane-covered corneas had less inflammatory response at 1 and 3 days, less keratocyte apoptosis in the ablated anterior corneal stroma at 1, 3, and 7 days (P < .001), and less stromal fibroblast cellularity and epithelial hyperplasia at 12 weeks. CONCLUSIONS: Amniotic membrane matrix introduced at an early stage of the corneal wound healing process effectively reduced corneal haze induced by excimer laser photoablation in rabbits. Studies linking suppression of apoptosis in the acute wound-healing process with reduction of subsequent corneal scarring may have useful clinical applications.
机译:目的:确定保留的人羊膜是否可以减少准分子激光光烧蚀兔角膜引起的角膜混浊和角膜细胞凋亡。方法:采用VISX Star激光和光疗角膜切除术(PTK)模式,对30只兔子进行了双侧准分子光消融,消融区域为6.0毫米,消融深度为120微米。一只眼睛随机被保存的人羊膜覆盖,该羊膜用4条间断的10-0尼龙缝线固定,另一只眼睛作为对照。在第1周取出羊膜,并由裂隙灯生物显微镜在3周内每3周由3名蒙面角膜专家对角膜混浊进行分级,直至杀死兔子。将另外18只兔子分为4个亚组,分别接受PTK,带膜的PTK,假缝合线的PTK或带睑缘镜检查的PTK。对所有眼睛进行组织学研究,并在第1、3和7天和12周分别通过原位末端脱氧核苷酸转移酶脱氧-UTP-缺口末端标记测定法对每组中的3只眼睛进行研究。结果:在三个蒙面观察者中,观察到了对照角膜和羊膜覆盖角膜之间角膜雾度评分差异的一致分级。在两组中,PTK后有组织的网状膜角膜混浊均在7周时达到峰值,而羊膜覆盖组的角膜混浊评分在7至12周时显着低于对照组(所有P <0.001)。与对照角膜相比,羊膜覆盖的角膜在第1天和第3天具有较少的炎症反应,在消融的前角膜基质在第1、3和7天具有较少的角膜细胞凋亡(P <.001),并且基质较少12周时成纤维细胞的细胞性和上皮增生。结论:在角膜伤口愈合过程的早期引入的羊膜基质有效地减少了准分子激光光烧蚀引起的兔角膜混浊。急性伤口愈合过程中抑制细胞凋亡与减少随后的角膜瘢痕形成联系的研究可能具有有用的临床应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号