首页> 外文期刊>Journal of cataract and refractive surgery >Removing silicone oil droplets from the posterior surface of silicone intraocular lenses.
【24h】

Removing silicone oil droplets from the posterior surface of silicone intraocular lenses.

机译:从硅树脂人工晶状体后表面去除硅油滴。

获取原文
获取原文并翻译 | 示例
           

摘要

A 67-year-old woman had droplets of silicone oil adhering to her silicone intraocular lens (IOL) resulting from a previous silicone oil tamponade. A lens hook and intraocular irrigation were used in conjunction by inserting an infusion cannula to remove the droplets. This restored clarity of the visual axis, improved visual acuity, and eliminated the need for IOL replacement. The technique is simple and less invasive than IOL exchange and may become the preferred way to remove silicone droplets from an IOL.
机译:一名67岁的妇女因先前的硅油填塞物而在她的硅树脂人工晶状体(IOL)上粘附了硅油液滴。通过插入输液套管以去除液滴,可以同时使用镜钩和眼内冲洗。这样可以恢复视轴的清晰度,提高视敏度,并且无需更换IOL。该技术比IOL交换简单,侵入性小,并且可能成为从IOL去除硅滴的首选方法。