首页> 外文期刊>Journal of cataract and refractive surgery >Clinical results using the Holladay 2 intraocular lens power formula.
【24h】

Clinical results using the Holladay 2 intraocular lens power formula.

机译:临床结果采用Holladay 2人工晶状体屈光力公式。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To analyze the accuracy of the Holladay 2 formula, which has been proposed as an improvement over the original Holladay formula. METHODS: This retrospective analysis comprised 317 eyes operated on by 1 surgeon using 1 technique and 1 intraocular lens style in a specialty practice. Because the Holladay 2 formula has yet to be published, its accuracy can only be analyzed using the commercially available Holladay IOL Consultant computer program to compare it to the Holladay 1, Hoffer Q, and SRK/T formulas. Defined axial length ranges were analyzed individually. RESULTS: A lower mean absolute error (MAE) trend was found for the average length eye (22.0 to 24.5 mm) by the Holladay 1 and Hoffer Q formulas. For short eyes (< 22.0 mm), the Hoffer Q and Holladay 2 perform better. The SRK/T consistently showed a trend toward the lowest MAE in all long eyes (>24.5 mm) as well as the subdivisions of medium long (24.5 to 26.0 mm) and very long (>26.0 mm). The Holladay 2 trended toward the least accurate (MAE) of the 4 formulas in all ranges of axial length except the shortest and the very longest. It appears to perform poorer in average and medium long eyes. CONCLUSIONS: Although the Holladay 2 formula has improved its MAE accuracy in short eyes, it was not more accurate than the Hoffer Q. The changes made in the formula to effect this improvement in MAE seem to have sacrificed the accuracy of the original Holladay formula in eyes with average and medium long axial lengths.
机译:目的:分析Holladay 2公式的准确性,该公式已被提议作为对原始Holladay公式的改进。方法:这项回顾性分析包括由一名外科医生使用一种技术和一种特殊的眼内晶状体样式手术的317眼。由于Holladay 2公式尚未发布,因此只能使用市售的Holladay IOL Consultant计算机程序来分析其准确性,以将其与Holladay 1,Hoffer Q和SRK / T公式进行比较。定义的轴向长度范围分别进行了分析。结果:通过Holladay 1和Hoffer Q公式,发现平均眼长(22.0至24.5 mm)的平均绝对误差(MAE)趋势较低。对于短眼(<22.0毫米),Hoffer Q和Holladay 2性能更好。 SRK / T在所有长眼(> 24.5 mm)以及中长(24.5至26.0 mm)和极长(> 26.0 mm)的细分中始终显示出最低MAE的趋势。 Holladay 2在所有轴向长度范围内都趋向于4个公式中的最不精确(MAE),但最短和最长的除外。它的平均和中等长眼睛表现较差。结论:尽管Holladay 2公式在短眼中提高了其MAE精度,但它并不比Hoffer Q更为准确。为实现MAE的这一改进而对公式进行的更改似乎牺牲了原始Holladay公式的准确性。眼睛具有中等和中等长的轴向长度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号