Purpose: To examine visual function after targeting -2.0 diopter (D) spherical equivalent (SE) when implanting a multifocal intraocular lens (IOL) in eyes with cataract and age-related macular degeneration (AMD). Setting: Three private practices. Design: Case series. Methods: Lenses of cataractous eyes with AMD were replaced with the Acrysof Restor SN60D3 multifocal IOL, targeting an SE of -2.0 D, which yielded +5.2 D near addition. Near and distance visual acuities were examined. Patients completed a visual function questionnaire preoperatively and 6 months postoperatively. Results: At 6 months, 13 patients with 20 eligible eyes were examined. The uncorrected near visual acuity improved in 18 eyes (90%) and was unchanged in 2 eyes. The corrected distance visual acuity improved in 14 eyes (70%), was unchanged in 4 eyes (20%), and decreased (≤3 lines) in 2 eyes (10%). All vision-related questionnaire items improved. Conclusion: For cataractous eyes with AMD, replacing the crystalline lens with this myopia-targeted multifocal IOL improved or maintained near vision without severely compromising distance vision. Financial Disclosure: Drs. Mackool and Ernest are consultants to Alcon. Dr. Mackool is an inventor in the patent of the IOLs related to this strategy. No other author has a financial or proprietary interest in any material or method mentioned.
机译:目的:当在患有白内障和年龄相关性黄斑变性(AMD)的眼睛中植入多焦点人工晶状体(IOL)时,检查瞄准-2.0屈光度(D)球当量(SE)后的视觉功能。地点:三种私人惯例。设计:案例系列。方法:用Acrysof Restor SN60D3多焦点IOL替换具有AMD的白内障晶状体,目标SE为-2.0 D,近加时产生+5.2D。检查近视和远视视力。患者在术前和术后6个月完成了视觉功能问卷调查。结果:在6个月时,检查了13例具有20只合格眼睛的患者。 18眼(90%)的未矫正近视敏度改善,2眼未改变。矫正远距离视力提高了14眼(70%),未改变的4眼(20%),下降了(≤3行)的2眼(10%)。所有与视觉有关的问卷调查项目均得到改善。结论:对于患有白内障的白内障眼,用这种以近视为目标的多焦点IOL替代晶状体可改善或维持近视力,而不会严重损害远视力。财务披露:Dr. Mackool和Ernest是爱尔康的顾问。 Mackool博士是与此策略相关的IOL专利的发明人。其他任何作者都不会在提及的任何材料或方法中拥有财务或所有权利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号