PURPOSE: To evaluate the refractive and surgical outcomes of cataract surgery with toric intraocular lens (IOL) implantation performed at a teaching institution. SETTING: Miami Veterans Affairs Medical Center, Miami, Florida, USA. DESIGN: Retrospective case series. METHODS: All data were obtained by a retrospective chart review and entered into a standard computerized database for analysis. Main outcome measures included refractive and surgical outcomes after Acrysof toric IOL placement, including the deviation from the expected spherical and cylindrical correction and the incidence of ocular complications. RESULTS: The study comprised 94 eyes (80 patients). The mean deviation from the anticipated spherical correction (94 eyes) was +0.06 diopter (D) +/- 0.8 (range -2.6 D to +3.6 D), with 80% of eyes achieving a spherical equivalent within +/-1.00 D of the target refraction. The postoperative refractive cylinder was significantly reduced from baseline, with 79% of eyes having at least a 0.50 D improvement in astigmatism after surgery (P<.0005). The mean deviation from the anticipated refractive cylinder (85 eyes) was -0.48 +/- 1.2 D (range -5.0 to +2.8 D). The IOL was placed in an incorrect position in 2 patients, requiring a reoperation with IOL rotation into the proper axis. The mean follow-up was 7 months (range 1 to 28 months). CONCLUSION: The added complexity associated with toric IOL placement resulted in spherical and astigmatic improvements without compromising patient safety beyond a level inherent in resident-based cataract surgery.
机译:目的:评估在教学机构进行的复曲面人工晶状体(IOL)植入术的白内障手术的屈光和手术效果。地点:美国佛罗里达州迈阿密,迈阿密退伍军人事务医疗中心。设计:回顾案系列。方法:所有数据均通过回顾性图表审查获得,并输入标准计算机数据库进行分析。主要结局指标包括Acrysof复曲面IOL放置后的屈光和手术结局,包括与预期的球面和柱面矫正的偏差以及眼部并发症的发生率。结果:该研究包括94只眼(80例患者)。与预期的球面矫正(94眼)的平均偏差为+0.06屈光度(D)+/- 0.8(范围-2.6 D至+3.6 D),其中80%的眼球屈光度在+/- 1.00 D之内目标折射。术后屈光柱相对于基线明显减少,有79%的眼睛术后散光至少改善了0.50 D(P <.0005)。与预期的屈光柱(85眼)的平均偏差为-0.48 +/- 1.2 D(范围-5.0至+2.8 D)。 2例患者将IOL放置在错误的位置,需要再次手术,将IOL旋转到正确的轴上。平均随访时间为7个月(范围1到28个月)。结论:与复曲面人工晶状体放置相关的增加的复杂性导致了球形和散光的改善,同时又不损害患者的安全性,使其超越了常驻白内障手术固有的水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号