...
首页> 外文期刊>Journal of cataract and refractive surgery >Correlation of visual quality with satisfaction and function in a normal cohort of pseudophakic patients
【24h】

Correlation of visual quality with satisfaction and function in a normal cohort of pseudophakic patients

机译:假晶状体正常人群的视觉质量与满意度和功能的相关性

获取原文
获取原文并翻译 | 示例

摘要

Purpose: To select a normal post-cataract-surgery cohort, determine visual quality parameters, and compare these parameters with self-reported satisfaction and visual function. Setting: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Design: Retrospective cohort study. Methods: A cohort of pseudophakic patients was selected based on uneventful surgery, good corrected visual acuity (no worse than logMAR 0.02), and lack of ocular complaints or pathology including dry-eye syndrome or posterior capsule opacification. A single-piece high-refractive-index acrylic intraocular lens, age 50 or older, and at least 1 year out from surgery were other inclusion criteria. Testing included logMAR corrected distance visual acuity (CDVA), mesopic 10% contrast logMAR CDVA with and without glare, straylight determination, Rasch-modified National Eye Institute Visual Function questionnaire 11R (NEI VF-11R), custom pseudophakic dysphotopsia survey, and overall satisfaction question. Correlations were determined between these parameters. Results: Of the 2953 patients considered, 70 patients met all criteria, provided consent, and enrolled. Only pseudophakic dysphotopsia (r = -0.60; P<.0001) and the NEI VF-11R (r = -0.44; P<.0001) correlated with overall satisfaction. In addition, pseudophakic dysphotopsia correlated with the NEI VF-11R (r = 0.58; P<.0001). Conclusions: When evaluating a highly controlled population with expected high satisfaction after cataract surgery, pseudophakic dysphotopsia was clearly the only significant dissatisfier. Furthermore, dysphotopsia highly correlated with the NEI VF-11R questionnaire; thus, symptoms of dysphotopsia are also seen to have functional significance. A shortened NEI VFQ survey and satisfaction correlated strongly with the full survey. Financial Disclosure: Dr. Olson has been a consultant to Abbott Medical Optics, Inc., Becton, Dickinson and Co., and Allergan, Inc. He has received grant support from Abbott Medical Optics, Inc., and Allergan, Inc. No author has a financial or proprietary interest in any material or method mentioned.
机译:目的:选择正常的白内障手术后队列,确定视觉质量参数,并将这些参数与自我报告的满意度和视觉功能进行比较。地点:美国犹他州盐湖城,犹他大学John A. Moran眼科中心。设计:回顾性队列研究。方法:根据无畸形手术,矫正视力(不低于logMAR 0.02),无眼疾或包括干眼综合征或后囊混浊在内的病理情况,选择一组假晶状体患者。其他纳入标准包括年龄大于或等于50岁且手术后至少1年的单片高折射率丙烯酸人工晶状体。测试包括logMAR校正的远视力(CDVA),有和没有眩光的中观10%对比logMAR CDVA,杂散光确定,Rasch改良的National Eye Institute视觉功能问卷11R(NEI VF-11R),定制的假晶状体视力障碍调查和总体满意度题。确定了这些参数之间的相关性。结果:在所考虑的2953名患者中,有70名患者符合所有标准,提供了同意并入组。只有假晶状体性视疲劳症(r = -0.60; P <.0001)和NEI VF-11R(r = -0.44; P <.0001)与总体满意度相关。此外,假晶状体性视疲劳与NEI VF-11R相关(r = 0.58; P <.0001)。结论:当评估高度控制的人群并在白内障手术后获得预期的高满意度时,假晶状体营养不良显然是唯一明显的不满意之处。此外,烦躁不安与NEI VF-11R问卷高度相关。因此,视力障碍的症状也被认为具有功能意义。缩短的NEI VFQ调查和满意度与整个调查密切相关。财务披露:奥尔森博士曾担任雅培医疗光学公司,Becton,Dickinson and Co.和Allergan,Inc.的顾问。他获得了雅培医疗光学公司和Allergan,Inc.的赠款支持。在上述任何材料或方法中拥有财务或专有权益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号