...
首页> 外文期刊>Journal of cataract and refractive surgery >Shape of the anterior cornea: Comparison of height data from 4 corneal topographers
【24h】

Shape of the anterior cornea: Comparison of height data from 4 corneal topographers

机译:角膜前缘的形状:4位角膜地形图师的身高数据比较

获取原文
获取原文并翻译 | 示例

摘要

Purpose: To compare the ability of clinical corneal topographers to describe the shape of the anterior cornea for optical modeling. Setting: University Medical Center Groningen, Groningen, Netherlands. Design: Cross-sectional study. Methods: The anterior corneal shape of healthy subjects was assessed with 4 topographers (Atlas Placido disk, Galilei dual Scheimpflug, Orbscan scanning slit, Pentacam single Scheimpflug). Exported height data were fit with Zernike polynomials. Mean values with the standard deviation, interdevice variability, and test-retest variability were determined for the defocus Z(2,0), astigmatism Z(2,-2) and Z(2,2), coma Z(3,-1) and Z(3,1), and spherical aberration Z(4,0) coefficients for 5.5 mm and 8.0 mm diameters. Results: At 5.5 mm, the single Scheimpflug topographer showed the smallest coefficient of repeatability; 0.31 μm for Z(2,0); 0.40 and 0.34 μm for Z(2,-2) and Z(2,2), respectively; 0.15 and 0.11 μm for Z(3,-1) and Z(3,1), respectively; and 0.08 μm for Z(4,0); the other topographers showed up to 10 times larger coefficients of repeatability. The (unsigned) mean differences between the topographers were in the range of 0.20 to 1.21 μm for Z(2,0); 0.02 to 0.31 μm and 0.06 to 0.42 μm for Z(2,-2) and Z(2,2), respectively; 0.03 to 0.18 μm and 0.03 to 0.35 μm for Z(3,-1) and Z(3,1), respectively; and 0.00 to 0.14 μm for Z(4,0). The Placido-disk topographer and single Scheimpflug topographer data corresponded best. Similar trends were found at 8.0 mm. Conclusion: Test-retest variability hampered a detailed description of the anterior corneal shape at the level of individual subjects; interdevice variability compromises the exchangeability of the devices. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.
机译:目的:为了比较临床角膜地形图师描述光学模型的前角膜形状的能力。地点:荷兰格罗宁根大学格罗宁根大学医学中心。设计:横断面研究。方法:用4位地形图师(Atlas Placido盘,Galilei双Scheimpflug,Orbscan扫描狭缝,Pentacam单Scheimpflug)评估健康受试者的前角膜形状。导出的高度数据符合Zernike多项式。确定散焦Z(2,0),散光Z(2,-2)和Z(2,2),昏迷Z(3,-1)的标准偏差,装置间变异性和重测变异性的平均值)和Z(3,1),以及直径为5.5 mm和8.0 mm的球差Z(4,0)系数。结果:在5.5 mm处,单个Scheimpflug地形图仪显示出最小的可重复性系数。 Z(2,0)为0.31μm; Z(2,-2)和Z(2,2)分别为0.40和0.34μm; Z(3,-1)和Z(3,1)分别为0.15和0.11μm; Z(4,0)为0.08μm;其他地形图显示的重复系数高达10倍。对于Z(2,0),地形设计师之间的(无符号的)平均差异在0.20至1.21μm的范围内; Z(2,-2)和Z(2,2)分别为0.02至0.31μm和0.06至0.42μm; Z(3,-1)和Z(3,1)分别为0.03至0.18μm和0.03至0.35μm;对于Z(4,0)为0.00至0.14μm。 Placido磁盘地形图仪和单个Scheimpflug地形图仪数据对应得最好。在8.0毫米处发现了类似的趋势。结论:重测变异性阻碍了个体受试者对角膜前缘形状的详细描述;设备间的可变性损害了设备的可交换性。财务披露:没有任何作者对所提及的任何材料或方法有财务或专有利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号