首页> 外文期刊>Journal of cataract and refractive surgery >Comparison of Goldmann applanation and dynamic contour tonometry before and after cataract surgery
【24h】

Comparison of Goldmann applanation and dynamic contour tonometry before and after cataract surgery

机译:白内障手术前后戈德曼压平法和动态轮廓眼压计的比较

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Purpose: To validate changes in intraocular pressure (IOP) after phacoemulsification with intraocular lens (IOL) implantation without pressure-lowering surgery in previously unoperated eyes of normal and glaucoma patients. Setting: University Eye Clinic, Otto-von-Guericke-University, Magdeburg, Germany. Design: Cohort study. Methods: The IOP in both eyes of patients was determined by Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT) 1 to 2 days before and after uneventful unilateral surgery. Central corneal thickness was used to correct raw GAT readings. Results: Of the 50 patients having unilateral phacoemulsification, 29 had had cataract extraction in the contralateral eye. The mean baseline IOP was 17.4 ± 4.4 mm Hg (GAT) and 16.6 ± 2.9 mm Hg (DCT). Postoperatively, the GAT IOP decreased to 16.4 ± 6.5 mm Hg and the DCT IOP increased slightly to 17.1 ± 4.1 mm Hg. The mean tonometer difference (ΔIOP = GAT - DCT) amounted to ΔIOP pre = +0.75 ± 2.69 mm Hg in phakic eyes and ΔIOP post = -0.70 ± 3.76 mm Hg in pseudophakic eyes (P=.0011). Consistent results were found in pairs of phakic eyes and pseudophakic eyes (mean IOP 18.0 ± 4.8 mm Hg [GAT] and 17.0 ± 3.3 mm Hg [DCT]). In fellow eyes, the mean GAT reading was 13.4 ± 4.4 mm Hg and the mean DCT value, 14.8 ± 2.4 mm Hg. ΔIOP phakic was +1.04 ± 2.75 mm Hg and ΔIOP pseudophakic was -1.48 ± 2.78 mm Hg (P=.00000021). Conclusions: The GAT IOP readings in pseudophakic eyes seemed to be falsely low. Hence, special attention in the screening, diagnosis, and management of glaucoma is necessary. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.
机译:目的:为了验证在正常和青光眼患者以前未手术的眼睛中,在未进行降压手术的情况下进行超声乳化联合人工晶状体(IOL)植入术后眼内压(IOP)的变化。地点:德国马格德堡奥托冯格里克大学大学眼科诊所。设计:队列研究。方法:在无畸胎的单侧手术前后1到2天,通过Goldmann压平眼压计(GAT)和动态轮廓眼压计(DCT)测定患者双眼的IOP。中央角膜厚度用于校正原始GAT读数。结果:在50例单侧超声乳化术中,有29例对侧眼有白内障摘除术。平均基线IOP为17.4±4.4 mm Hg(GAT)和16.6±2.9 mm Hg(DCT)。术后,GAT IOP降至16.4±6.5 mm Hg,而DCT IOP则微升至17.1±4.1 mm Hg。人工晶状体眼的平均眼压差(ΔIOP= GAT-DCT)等于ΔIOPpre = +0.75±2.69 mm Hg,假晶状体眼的ΔIOPpost = -0.70±3.76 mm Hg(P = .0011)。在有晶状体眼和假晶状体眼中发现了一致的结果(平均眼压18.0±4.8 mm Hg [GAT]和17.0±3.3 mm Hg [DCT])。在同一个眼睛中,平均GAT读数为13.4±4.4 mm Hg,平均DCT值为14.8±2.4 mm Hg。 ΔIOP晶状体为+1.04±2.75 mm Hg,ΔIOP拟晶状体为-1.48±2.78 mm Hg(P = .00000021)。结论:假晶状体眼中的GAT IOP读数似乎错误地低。因此,在青光眼的筛查,诊断和治疗中需要特别注意。财务披露:没有任何作者对所提及的任何材料或方法有财务或专有利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号