首页> 外文期刊>Journal of cataract and refractive surgery >Vector analysis of astigmatic changes after cataract surgery with implantation of a new toric multifocal intraocular lens.
【24h】

Vector analysis of astigmatic changes after cataract surgery with implantation of a new toric multifocal intraocular lens.

机译:白内障手术后植入新的复曲面多焦点人工晶状体的散光变化的矢量分析。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To analyze the astigmatic changes after cataract surgery with the implantation of a new toric multifocal intraocular lens (IOL) using the Alpins vector method. SETTING: Vissum-Instituto de Oftalmologico de Alicante, Alicante, Spain. DESIGN: Prospective case series. METHODS: After cataract surgery with implantation of an AT Lisa 909M toric multifocal IOL, the visual, refractive, corneal topographic, internal astigmatism, defocus curves, and contrast sensitivity outcomes were evaluated over 6 months. Refractive astigmatic changes (target astigmatism [TIA]; surgically induced astigmatism [SIA]; difference vector; magnitude of error; flattening effect; torque) were analyzed using the Alpins vectorial method. RESULTS: The study enrolled 23 eyes (12 patients). Postoperatively, there was a significant reduction in refractive cylinder (P < .01) with an associated visual improvement for near (P = .03) and distance (P=.01). The magnitude of SIA vector was significantly larger than the TIA 3 months postoperatively (P = .03). The mean magnitude of the difference vector was 0.67 diopter (D) +/- 0.51 (SD) at 6 months. The mean magnitude of error remained positive and close to zero over the entire follow-up (P >/= .19). The mean magnitude of torque vector was 0.49 +/- 0.54 D at 6 months. Significant positive correlation was found between the magnitude of torque and the difference vector (r >/= 0.70, P<.01). CONCLUSION: The new toric IOL restored distance and near visual function with excellent predictability in eyes with moderate to high corneal astigmatism having cataract surgery.
机译:目的:分析使用Alpins矢量方法植入新的复曲面多焦点人工晶状体(IOL)后的白内障手术后的散光变化。地点:西班牙阿利坎特,阿利坎特市立圣母学院。设计:预期案例系列。方法:在白内障手术后植入AT Lisa 909M复曲面多焦点IOL,在6个月内评估了视觉,屈光,角膜地形图,内部散光,散焦曲线和对比敏感度结果。使用Alpins矢量方法分析了屈光散光变化(目标散光[TIA];手术引起的散光[SIA];差矢量;误差幅度;展平效果;扭矩)。结果:该研究招募了23只眼(12例患者)。术后,屈光度数显着减少(P <.01),并且近视(P = .03)和远视(P = .01)的相关视力改善。术后3个月SIA载体的大小显着大于TIA(P = .03)。在6个月时,差异向量的平均大小为0.67屈光度(D)+/- 0.51(SD)。在整个随访过程中,平均误差幅度始终为正,接近于零(P> / = .19)。在6个月时,转矩矢量的平均大小为0.49 +/- 0.54D。在扭矩大小和差矢量之间发现显着正相关(r> / = 0.70,P <.01)。结论:新的复曲面人工晶体在白内障手术的中度至高度角膜散光的眼睛中恢复了远近视功能,具有良好的可预测性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号