BACKGROUND: The variability of peroneal reaction time measurements is a major problem when using this parameter to control rehabilitation or proprioceptive training processes. In order to control peroneal reaction time values, some extrinsic factors should be considered. The purpose of this study was to measure peroneal reaction time in unipodal stance for two different destabilization axes. METHODS: The peroneal reaction time of 10 healthy subjects was measured from kinematic and electromyograhic data in an experimental study using an ankle destabilization device. FINDINGS: In a preliminary analysis, results showed that the destabilization axis orientation did not affect peroneal reaction time values (68.5 ms, standard deviation=9.5 ms and 71.5 ms, standard deviation=8 ms for destabilizations in the frontal plane and around the Henke's axis, respectively). However, the inter-trial variance of inversion velocity peaks explained between 40% and 49% of the peroneal reaction time variance. When trials were selected on the basis of homogeneous inversion velocity peaks, results showed that peroneal reaction time values for the peroneus brevis were shorter during inversion movements performed around the physiological Henke's tilting axis (63 ms, standard deviation=9 ms vs. 71 ms, standard deviation=8 ms). INTERPRETATION: Our findings evidenced that tilting axis orientation must be considered as an extrinsic factor that may influence peroneal reaction time. Moreover it also seems necessary to consider inversion speed values to adequately compare peroneal reaction time values.
机译:背景:腓骨反应时间测量的可变性是使用此参数控制康复或本体感受训练过程时的主要问题。为了控制腓骨的反应时间值,应考虑一些外在因素。这项研究的目的是在两个不同的不稳定轴上以单足姿势测量腓骨的反应时间。方法:使用脚踝去稳定装置,通过一项运动研究和运动肌电数据测量了10名健康受试者的腓骨反应时间。结果:在初步分析中,结果表明去稳定轴的方向不影响腓骨反应时间值(68.5 ms,标准偏差= 9.5 ms和71.5 ms,标准偏差= 8 ms,用于额叶面和Henke轴周围的去稳定作用) , 分别)。但是,反转速度峰值的试验间方差解释了腓骨反应时间方差的40%至49%之间。当根据均一的反转速度峰值选择试验时,结果表明,在围绕生理学Henke倾斜轴进行反转运动期间,腓骨短腓骨的腓骨反应时间值较短(63 ms,标准偏差= 9 ms vs. 71 ms,标准偏差= 8毫秒)。解释:我们的发现表明,必须将倾斜轴方向视为可能影响腓骨反应时间的外部因素。此外,似乎还需要考虑反转速度值以充分比较腓骨反应时间值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号