The relationship between EMG median frequency and low frequency band amplitude changes at different levels of muscle capacity.

机译:EMG中值频率和低频频带幅度之间的关系在不同的肌肉容量水平上会发生变化。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objective. To test the validity of high and low frequency band amplitudes of the surface electromyography (EMG) profile as representation of muscle fatigue.Design. A within subjects (n=10) repeated measures design was used to collect surface EMG signals from the biceps during an isometric contraction under two levels of fatigue status.Background. The use of the shift in the median frequency of the surface EMG power spectrum is a well known method of assessing muscle fatigue. Fatigue also results in amplitude changes of the specific frequency bands. The use of frequency band analysis may be an alternative option for the assessment of muscle fatigue in specific experimental settings.Methods. Surface EMG profiles of the biceps were recorded at 1024 Hz during a sustained isometric hold at 60% of the individuals fresh and fatigued maximal voluntary isometric torque. The median frequency of the power spectrum was compared with changes in the low frequency (15-45 Hz) and high frequency (>95 Hz) bands.Results. There was a close association between median frequency shift and the amplitude of the 15-45 Hz bandwidth and the high-low frequency amplitude ratio. The association was similar for performance under different muscle capacity states.Conclusions. Frequency band amplitude analysis provides similar information to median frequency shift under isometric conditions and may be suited to specific experimental protocols in workplace fatigue studies.RelevanceThe use of amplitude band analysis that closely approximates the standard median frequency changes allows greater possibility of assessing muscle fatigue in different experimental settings and the use of lower sampling rates.
机译:目的。为了测试表面肌电图(EMG)曲线的高频带和低频带幅度作为肌肉疲劳表示的有效性。设计。受试者内部(n = 10)的重复测量设计用于在两个疲劳状态下等距收缩期间从二头肌收集表面肌电信号。使用表面肌电图功率谱的中值频率的偏移是评估肌肉疲劳的众所周知的方法。疲劳还会导致特定频段的幅度变化。频带分析的使用可能是在特定实验环境中评估肌肉疲劳的替代选择。在持续60分钟的等距保持期间,二头肌的表面EMG轮廓记录为1024 Hz,其中60%的人保持新鲜和疲劳的最大自愿等距扭矩。将功率谱的中值频率与低频(15-45 Hz)和高频(> 95 Hz)频段的变化进行比较。中值频移与15-45 Hz带宽的幅度以及高低频幅度比之间存在密切的联系。在不同肌肉容量状态下的表现相似。结论。频带幅度分析可提供与等距条件下中值频移相似的信息,并且可能适用于工作场所疲劳研究中的特定实验方案。相关性使用紧密接近标准中值频率变化的幅度带分析可以更好地评估不同部位的肌肉疲劳实验设置和使用较低的采样率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号