BACKGROUND: Mechanical properties of the human patellar tendon are largely based on cadaver studies, which may not necessarily be applicable to the human patellar tendon, in vivo. While ultrasonography is an attractive non-invasive method for studying human, in vivo, muscle-tendon behaviour, it has mostly been used to examine Achilles tendon properties. We examine the accuracy of human patellar tendon elongation, in vivo, and its within-day and between-day reproducibility. METHODS: Subjects performed four maximal 10-s ramp isometric knee extension trials to examine within-day reproducibility, and the procedure was repeated on a separate day to assess between-day reproducibility. Continuous and simultaneous ultrasonography based measurement of both tibial and patellar movement together with patellar tendon force yielded mechanical estimates. RESULTS: Longitudinal tibial displacement corresponded to 45 (SEM 8) % of the overall tibia-patella displacement. For within-day reproducibility there was no difference between trials for stiffness [trial a, 4334 (SEM 562) N/mm; trial b, 4273 (SEM 533) N/mm], strain [trial a, 6.9 (SEM 0.6) %; trial b, 6.8 (SEM 0.7) %] or elastic modulus [trial a, 1.09 (SEM 0.12) GPa; trial b, 1.09 (SEM 0.10) GPa]. The within day correlation coefficient and typical error were 0.95 and 9.9% for stiffness, 0.97 and 5.5% for strain, and 0.94 and 9.4% for elastic modulus. The corresponding values for between days were 0.94 and 8.7% for stiffness, 0.98 and 3.7% for strain, and 0.86 and 9.6% for elastic modulus. INTERPRETATION: The present methodology of assessing human patellar tendon elongation, strain and stiffness, in vivo, is accurate and reproducible which permits its use in future investigations of patellar tendon biomechanics and the potential effects of various interventions.
机译:背景:人pa肌腱的机械性能主要基于尸体研究,在体内可能不一定适用于人pa肌腱。尽管超声检查是研究人,体内肌肉腱行为的一种有吸引力的非侵入性方法,但超声检查主要用于检查跟腱的特性。我们检查了人类pa骨肌腱伸长的准确性,在体内及其在一天之内和一天之间的可重复性。方法:受试者进行了四个最大的10秒斜坡等距膝盖伸展试验,以检查一天内的可重复性,并在另一天重复该过程以评估一天之间的可重复性。基于连续和同时的超声检查对胫骨和pa骨运动以及tend骨肌腱力的测量得出了机械估计值。结果:纵向胫骨移位相当于胫骨-骨总移位的45%(SEM 8)。对于一天内的可重复性,两次试验之间的硬度没有差异[试验a,4334(SEM 562)N / mm;试验b,4273(SEM 533)N / mm],应变[试验a,6.9(SEM 0.6)%;试验b,6.8(SEM 0.7)%]或弹性模量[试验a,1.09(SEM 0.12)GPa;试验b,1.09(SEM 0.10)GPa]。日内相关系数和典型误差的刚度分别为0.95和9.9%,应变为0.97和5.5%,弹性模量为0.94和9.4%。天之间的相应值的刚度分别为0.94和8.7%,应变为0.98和3.7%,弹性模量为0.86和9.6%。解释:目前在体内评估人pa肌腱伸长,应变和刚度的方法是准确且可重现的,从而使其可用于将来的tell肌腱生物力学研究以及各种干预措施的潜在影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号