A simple and sensitive method for the sequential determination of phosphate and arsenate was developed based on initial ion chromatographic separation followed by detection as the ion-association complex formed by heteropolymolybdophosphate and arsenate with bismuth. With 200 μl sample injection and separation on a AS4A-SC column using an eluent of 3.5 mM sodium hydrogen carbonate-10.0 mM sodium hydroxide, the detection limits which are calculated as the concentration equivalent to twice the baseline noise, were found to be 0.8 μg/1 and 4.2 μg/1 for P and As, respectively. Spiked samples were analyzed and recoveries were found to be satisfactory in the range of 95-105% for phosphate and 90-105% for arsenate. Samples of water and hair were analyzed by the proposed method.
机译:建立了一种简单而灵敏的顺序测定磷酸盐和砷酸盐的方法,该方法基于初始离子色谱分离,然后检测为杂多钼酸磷酸盐和砷酸盐与铋形成的离子缔合络合物。在使用3.5 mM碳酸氢钠-10.0 mM氢氧化钠的洗脱液的AS4A-SC色谱柱上进样200μl样品并分离时,发现检测限为0.8μg,计算出的浓度为相当于基线噪声两倍的浓度P和As分别为/ 1和4.2μg/ 1。分析了加标样品,发现回收率令人满意,磷酸盐的回收率在95-105%,砷酸盐的回收率在90-105%。通过提出的方法分析水和头发的样品。