BACKGROUND: Rapid and simple methods for diagnosing human influenza A (H5N1) disease urgently needed. The limited data so far suggest that the currently available rapid antigen detection kits have poor clinical sensitivity for diagnosis of human H5N1 disease. OBJECTIVES: To compare the analytical sensitivity of six commercially available rapid antigen detection kits for the detection of "human" (subtypes H1N1, H3N2) and "avian" (subtype H5N1) influenza A viruses. STUDY DESIGN: Six commercially available test kits for the detection of influenza A were investigated. Analytic sensitivity for the detection of two contemporary H1N1, two H3N2 and three H5N1 viruses was determined using virus culture as a reference method. RESULTS AND CONCLUSIONS: Each test kit detected the H5N1 virus subtypes as efficiently as they detected conventional human viruses of subtypes H1N1 or H3N2. However, limits of detection of influenza viruses of all subtypes by antigen detection kits were >1000-fold lower than virus isolation. Thus, the reportedly poor clinical sensitivity of these antigen detection kits for diagnosis of patients with H5N1 disease is not due to a difference of sensitivity for detecting avian influenza H5N1 compared to human influenza viruses.
机译:背景:急需一种快速,简单的诊断人类甲型流感(H5N1)疾病的方法。到目前为止,有限的数据表明,当前可用的快速抗原检测试剂盒对人类H5N1疾病的诊断具有较差的临床敏感性。目的:比较六种市售快速抗原检测试剂盒对“人”(H1N1,H3N2亚型)和“禽”(H5N1亚型)甲型流感病毒的分析灵敏度。研究设计:研究了六种用于检测甲型流感的市售检测试剂盒。使用病毒培养作为参考方法确定了检测两种当代H1N1,两种H3N2和三种H5N1病毒的分析灵敏度。结果与结论:每种检测试剂盒检测H5N1病毒亚型的效率均与检测常规H1N1或H3N2亚型人类病毒的效率相同。但是,通过抗原检测试剂盒检测所有亚型的流感病毒的极限比病毒分离低1000倍以上。因此,据报道,这些抗原检测试剂盒对H5N1疾病患者的诊断的临床敏感性较差,并不是由于与人类流感病毒相比,检测禽流感H5N1的敏感性不同。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号