Using the morphology of photoplethysmogram peaks to detect changes in posture.

机译:使用光电容积描记图峰的形态来检测姿势的变化。

获取原文
获取原文并翻译 | 示例
           

摘要

The morphology of the pulsatile component of the photoplethysmogram (PPG) has been shown to vary with physiology, but changes in the morphology caused by the baroreflex response to orthostatic stress have not been investigated.Using two FDA approved Nonin(R) pulse oximeters placed on the finger and ear, we monitored 11 subjects, for three trials each, as they stood from a supine position. Each cardiac cycle was automatically extracted from the PPG waveform and characterized using statistics corresponding to normalized peak width, instantaneous heart rate, and amplitude of the pulsatile component of the ear PPG. A nonparametric Wilcoxon rank sum test was then used to detect in real-time changes in these features with p < 0.01.In all 33 trials, the standing event was detected as an abrupt change in at least two of these features, with only one false alarm. In 26 trials, an abrupt change was detected in all three features, with no false alarms. An increase in the normalize peak width was detected before an increase in heart rate, and in 21 trials a peak in the feature was detected before or as standing commenced. During standing, the pulse rate always increases, and then amplitude of the ear PPG constricts by a factor of two or more.We hypothesis that the baroreflex first reduces the percentage of time blood flow is stagnant during the cardiac cycle, then increases the hear rate, and finally vasoconstricts the peripheral tissue in order to reestablishing a nominal blood pressure. These three features therefore can be used as a detector of the baroreflex response to changes in posture or other forms of blood volume sequestration.
机译:已证明光体积描记器(PPG)搏动成分的形态会随生理变化,但尚未研究由对体位压力的压力反射反应引起的形态变化。使用两个FDA批准的Nonin(R)脉搏血氧仪在他们的手指和耳朵处于仰卧位的情况下,我们监测了11位受试者,每组进行了3次试验。每个心动周期均从PPG波形中自动提取,并使用与归一化峰宽,瞬时心率和耳朵PPG搏动分量幅度相对应的统计数据进行表征。然后使用非参数Wilcoxon秩和检验实时检测这些特征的变化,p <0.01。在所有33个试验中,站立事件被检测为至少其中两个特征的突然变化,只有一个错误报警。在26个试验中,在所有三个功能中均检测到突然变化,没有错误警报。在心率增加之前检测到归一化峰宽增加,在21个试验中,站立前或站立时检测到特征峰。在站立期间,脉搏频率总是增加,然后耳朵PPG的振幅收缩两倍或更多倍。我们假设压力反射首先会减少心动周期中血流停滞的时间百分比,然后增加听力最后,血管收缩外周组织以恢复正常血压。因此,这三个特征可以用作对姿势变化或其他形式的血容量隔离的压力反射反应的检测器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号