...
首页> 外文期刊>Journal of cardiovascular electrophysiology >Single-catheter technique for pulmonary vein antrum isolation: is it sufficient to identify and close the residual gaps without a circular mapping catheter?
【24h】

Single-catheter technique for pulmonary vein antrum isolation: is it sufficient to identify and close the residual gaps without a circular mapping catheter?

机译:单导管技术隔离肺静脉窦:是否需要在没有圆形测绘导管的情况下识别并关闭残留间隙?

获取原文
获取原文并翻译 | 示例

摘要

OBJECTIVES: The present study was designed to investigate the feasibility and efficacy of single ablation catheter for complete circumferential pulmonary vein antrum (PVA) isolation. BACKGROUND: Complete isolation of pulmonary veins is the mainstay for atrial fibrillation (AF) ablation. This is usually performed under the guidance of a circular catheter. METHODS: One hundred and ten consecutive patients with paroxysmal AF were prospectively randomized into two groups: single-catheter approach (group 1) and double-catheter approach (group 2). After performing initial circumferential lesions, residual gaps were mapped and closed with single ablation catheter in group 1 or guided by a circular mapping catheter in group 2 using an electroanatomic mapping system (CARTO XP, Biosense-Webster Inc., Diamond Bar, CA, USA). RESULTS: Complete bilateral PVA isolation was achieved in 22 of the 110 patients after initial ablation. All residual gaps could be correctly identified by activation mapping using single ablation catheter. The distribution of these residual gaps was asymmetric. In group 1, 25 gaps along the right PVA lesions and 49 gaps along the left PVA lesions were identified. All the residual gaps were closed with single-catheter approach. In group 2, 28 gaps on the right side and 53 gaps on the left side were identified using a circular catheter and closed with further ablations. The procedure data and clinical outcomes between the two groups were comparable. CONCLUSIONS: Single ablation catheter technique is feasible and as effective as circular catheter mapping in localizing the residual gaps for PVA isolation during ablation of paroxysmal AF.
机译:目的:本研究旨在研究单根消融导管用于完全隔离周向肺静脉窦(PVA)的可行性和有效性。背景:完全隔离肺静脉是房颤消融的主要手段。这通常在圆形导管的引导下进行。方法:将110例阵发性房颤患者随机分为两组:单导管入路(第1组)和双导管入路(第2组)。在进行最初的周围病变后,使用电解剖标测系统(CARTO XP,Biosense-Webster Inc.,Diamond Bar,CA,美国)在第1组中用单个消融导管标测并封闭残余间隙,或在第2组中用圆形标测导管引导残留间隙。 )。结果:最初消融后110例患者中有22例完全双侧PVA隔离。所有残留间隙可通过使用单个消融导管的激活图来正确识别。这些残留间隙的分布是不对称的。在第1组中,右侧PVA病变有25个缝隙,左侧PVA病变有49个缝隙。所有残余间隙均用单导管方法弥合。在第2组中,使用圆形导管识别出右侧的28个缝隙和左侧的53个缝隙,并进一步消融。两组之间的程序数据和临床结果具有可比性。结论:单发消融导管技术在定位阵发性房颤消融过程中定位PVA隔离残余间隙方面是可行的,并且与圆形导管测绘一样有效。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号