Consistency of the CFAE phenomena using custom software for automated detection of complex fractionated atrial electrograms (CFAEs) in the left atrium during atrial fibrillation.

机译:使用自定义软件自动检测房颤期间左心房中复杂的心房电图(CFAE)的CFAE现象的一致性。

获取原文
获取原文并翻译 | 示例

摘要

INTRODUCTION: Complex fractionated atrial electrograms (CFAEs) have been described as a potential target for ablation of atrial fibrillation (AF). The purpose of this study is to assess the consistency of the CFAE phenomena using custom software for automated detection of CFAEs in the left atrium during AF. METHODS AND RESULTS: This prospective study included 10 patients referred for catheter ablation of symptomatic drug-refractory AF. Ten consecutive points at a single location (cluster) were acquired as electroanatomical points every 3 seconds. Atrial signals were automatically classified as CFAEs by the software algorithm. The number of intervals between 50 ms and 110 ms and in the voltage range 0.05-0.15 mV during the 2.5-second recordings was determined and referred to as the interval confidence level (ICL). A total of 2,226 points were acquired during mapping of AF. A dominant group of ICL using one of two different configurations of ICL fractionation was identified. A dominant group was defined as the ICL categorization occurring with greatest frequency in a given cluster of points. The results show the consistency ranged from 73%+/- 21 for the three-group configuration (ICL < or = 4; 4 < ICL < or = 7; ICL > 7) to 84%+/- 16 for the two-group configuration (ICL < or = 5; ICL > 5). CONCLUSION: This novel software offers an objective method for CFAE analysis during atrial fibrillation. CFAE consistency ranged from 73% to 84% with wide standard deviation. Automated detection of CFAEs may remove the pitfalls associated with subjective visual detection, thus removing one variable in comparative studies of using CFAEs as AF ablation targets.
机译:简介:复杂的心房电描记图(CFAEs)已被描述为消融房颤(AF)的潜在目标。这项研究的目的是使用自定义软件评估房颤期间左心房CFAE的CFAE现象的一致性。方法与结果:这项前瞻性研究包括10例因症状性难治性AF导管消融转诊的患者。每3秒获取一个位置(集群)的十个连续点作为电解剖点。通过软件算法将心房信号自动分类为CFAE。在2.5秒的记录过程中,确定50毫秒至110毫秒之间的间隔数以及电压范围为0.05-0.15 mV,并将其称为间隔置信度(ICL)。在AF映射过程中总共获取了2,226个点。确定了使用ICL分级分离的两种不同配置之一的ICL的显性组。优势群定义为在给定的点簇中以最大频率出现的ICL分类。结果表明,一致性的范围从三组配置(ICL <或= 4; 4 7)的73%+ /-21到两组的84%+ /-16配置(ICL <或= 5; ICL> 5)。结论:这种新颖的软件为房颤期间CFAE分析提供了一种客观的方法。 CFAE浓度范围从73%到84%,标准偏差较大。 CFAE的自动检测可以消除与主观视觉检测相关的陷阱,因此在将CFAE作为AF消融靶标的比较研究中,消除了一个变量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号