Measurement of exhaled volatile organic compounds from patients with chronic obstructive pulmonary disease (COPD) using closed gas loop GC-IMS and GC-APCI-MS

机译:使用封闭气路GC-IMS和GC-APCI-MS测定慢性阻塞性肺疾病(COPD)患者呼出的挥发性有机化合物

获取原文
获取原文并翻译 | 示例
           

摘要

Due to its high sensitivity, compact size and low cost ion mobility spectrometry (IMS) has the potential to become a point-of-care breath analyzer. Therefore, we developed a prototype of a compact, closed gas loop IMS with gas chromatographic (GC) pre-separation and high resolving power of R = 90. In this study, we evaluated the performance of this GC-IMS under clinical conditions in a COPD study to find correlations between VOCs (10 ppb(v) to 1 ppm(v)) and COPD. Furthermore, in order to investigate possible correlations between ultra-low concentrated breath VOCs (0.1 ppt(v) to 1 ppb(v)) and COPD, a modified mass spectrometer (MS) with atmospheric pressure chemical ionization (APCI) and GC pre-separation (GC-APCI-MS) was used. The GC-IMS has been used in 58 subjects (21 smokers with moderate COPD, 12 ex-smokers with COPD, 16 healthy smokers and 9 non-smokers). GC-APCI-MS data were available for 94 subjects (21 smokers with moderate COPD, 25 ex-smokers with COPD, 25 healthy smokers and 23 non-smokers). For 44 subjects, a comparison between GC-IMS and GC-APCI-MS data could be performed. Due to service intervals, subject availability and corrupt data, patient numbers were different for GC-APCI-MS and GC-IMS measurements. Using GC-IMS, three VOCs have been found showing a significant difference between healthy controls and patients with COPD. In the GC-APCI-MS data, we only observed one distinctive VOC, which has been identified as 2-pentanone. This proof-of-principle study shows the potential of our high-resolution GC-IMS in the clinical environment. Due to different linear dynamic response ranges, the data of GC-IMS and GC-APCI-MS were only comparable to a limited extent.
机译:由于其高灵敏度,紧凑的尺寸和低成本的离子迁移谱(IMS),有可能成为即时护理呼吸分析仪。因此,我们开发了具有气相色谱(GC)预分离和R = 90的高分离能力的紧凑型密闭气环IMS的原型。在这项研究中,我们评估了该GC-IMS在临床条件下的性能。 COPD研究以发现VOC(10 ppb(v)至1 ppm(v))与COPD之间的相关性。此外,为了研究超低浓度呼吸VOC(0.1 ppt(v)到1 ppb(v))和COPD之间的可能关系,采用了带有大气压化学电离(APCI)和GC预色谱的改良型质谱仪(MS)分离(GC-APCI-MS)。 GC-IMS已用于58位受试者(21位中度COPD吸烟者,12位COPD前吸烟者,16位健康吸烟者和9位非吸烟者)。 GC-APCI-MS数据可用于94名受试者(21名中度COPD吸烟者,25名COPD前吸烟者,25名健康吸烟者和23名非吸烟者)。对于44位受试者,可以对GC-IMS和GC-APCI-MS数据进行比较。由于服务间隔,受试者可用性和数据损坏,GC-APCI-MS和GC-IMS测量的患者人数有所不同。使用GC-IMS,已发现三种VOC,显示健康对照与COPD患者之间存在显着差异。在GC-APCI-MS数据中,我们仅观察到一种独特的VOC,已被确定为2-戊酮。这项原理验证研究显示了我们高分辨率GC-IMS在临床环境中的潜力。由于线性动态响应范围不同,GC-IMS和GC-APCI-MS的数据只能在有限的范围内进行比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号