首页> 外文期刊>Journal of Adhesion Science and Technology: The International Journal of Theoredtical and Basic Aspects of Adhesion Science and Its Applications in All Areas of Technology >Efficacy of accelerated aging methods to degrade the adhesive interface of dentin cavities bonded with etch-and-rinse adhesive systems
【24h】

Efficacy of accelerated aging methods to degrade the adhesive interface of dentin cavities bonded with etch-and-rinse adhesive systems

机译:加速老化方法可降低与蚀刻和冲洗粘合剂系统粘合的牙本质腔的粘合界面的功效

获取原文
获取原文并翻译 | 示例
           

摘要

This study evaluated the bond durability produced by etch-and-rinse (E&R) adhesive systems in response to traditional and accelerated aging methods. Tridimensional dentin cavities were prepared on 80 bovine incisors, which were bonded with a 3-step E&R (Adper Scotchbond Multipurpose Plus - MP) and a 2-step E&R (Adper Single Bond 2 (SB) adhesive systems, and restored with composite. The samples were stored in water for 24 h, and then subjected to each of the aging methods (n=10): control group - only 24-h storage (not exposed to additional aging), 6- and 12-month water storage, and 10% NaOCl storage. The push-out bond strength test was performed in a universal testing machine. Failure modes were evaluated by scanning electron microscopy. Data were analyzed by two-way ANOVA and Tukey tests (p<0.05). Aging methods provided statistically similar bond strength for 3-step E&R adhesive system (p>0.05). 10% NaOCl storage provides statistically similar bond strength values to 6- and 12-month water storage (p>0.05), which were statistically lower than those provided by 24-h water storage (control group) (p<0.05). Adhesive failures were more frequent. Aging methods provided different behaviors according to each adhesive system. The accelerated 10% NaOCl storage was effective to decrease bond strength only for 2-step E&R adhesive system.
机译:这项研究评估了蚀刻和冲洗(E&R)粘合剂系统对传统和加速老化方法的响应所产生的粘合耐久性。在80个牛切牙上制备三维牙本质腔,将其与3步E&R(Adper Scotchbond Multipurpose Plus-MP)和2步E&R(Adper Single Bond 2(SB)粘合剂)粘合,并用复合材料修复。样品在水中保存24小时,然后采用每种老化方法(n = 10):对照组-仅保存24小时(不暴露于额外的老化条件),6个月和12个月的水存储,以及NaOCl储存量为10%,在万能试验机上进行推出粘结强度测试,通过扫描电子显微镜评估失效模式,通过双向ANOVA和Tukey测试分析数据(p <0.05),提供了统计方法3步E&R胶粘剂系统的粘结强度相似(p> 0.05)。10%NaOCl储存与6个月和12个月的储水量在统计学上相似(p> 0.05),统计学上低于24个月的水-h储水量(对照组)(p <0.05),粘附失败更多频繁。老化方法根据每个粘合剂系统提供不同的行为。加速的10%NaOCl储存仅对两步E&R粘合剂体系有效降低粘合强度。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号