首页> 外文期刊>Journal of burn care & research: official publication of the American Burn Association >Whole Arm Water Displacement Volumetry Is a Reliable and Sensitive Measure: A Pilot to Assess Acute Postburn Volume Change
【24h】

Whole Arm Water Displacement Volumetry Is a Reliable and Sensitive Measure: A Pilot to Assess Acute Postburn Volume Change

机译:全臂排水量测量是一种可靠而敏感的措施:评估急性烧伤后容积变化的飞行员

获取原文
获取原文并翻译 | 示例
       

摘要

Water displacement volumetry (WDV) is a reliable method for measurement of wrist and hand volume in lymphedema patients. However, within session WDV reliability for the whole upper limb (UL) lacks comprehensive investigation, particularly in acute edema populations. This study aimed to confirm the reliability and investigate the impact of time between repeated trials on the sensitivity of WDV as a measure of whole UL volume change in an uninjured cohort and a burn injured pilot group. Within session, duplicate measures of whole UL WDV were recorded in two groups of noninjured volunteers and a group of burn patients. Each noninjured group differed only in the time between WDV repeats. The reliability trials were performed <10 minutes apart (T-10) and 20 to 30 minutes apart (T-20). The time between repetitions for burn patients was 20 to 30 minutes, based on the results of the noninjured participant trials. All trial groups demonstrated excellent correlation between trials (ICCT10 = 0.999, ICCT20 = 0.997). The minimum detectable difference calculated for WDV when measuring whole UL volume change of >50 ml for noninjured and >100 ml for burn patients. Despite this, a systematic bias was demonstrated between the T-10 group means. The T-20 group trials did not indicate such error on statistical testing (P =.297). The study confirms that WDV measurement of whole ULs is reliable and sensitive, if used at least 20 minutes apart. However, a significant and clinically relevant subject-by-method interaction was demonstrated. Researchers and clinicians are reminded to be aware of the performance of the technique when designing investigations in patient populations.
机译:容积排水量(WDV)是测量淋巴水肿患者手腕和手部容积的可靠方法。然而,在会议期间,整个上肢(UL)的WDV可靠性缺乏全面的调查,尤其是在急性水肿人群中。这项研究旨在确认可靠性,并调查两次试验之间的时间间隔对WDV敏感性的影响,以作为未受伤队列和烧伤受伤飞行员组中整个UL体积变化的量度。在会议期间,在两组未受伤的志愿者和一组烧伤患者中记录了整个UL WDV的重复测量。每个未受伤的组仅在两次WDV重复之间的时间有所不同。可靠性试验的间隔时间少于10分钟(T-10),间隔时间少于20至30分钟(T-20)。根据未受伤参与者试验的结果,烧伤患者重复两次之间的时间为20至30分钟。所有试验组之间均显示出极好的相关性(ICCT10 = 0.999,ICCT20 = 0.997)。当测量未受伤的全部UL体积变化> 50 ml,烧伤患者的> 100 ml时,WDV计算得出的最小可检测差异。尽管如此,在T-10组平均值之间仍显示出系统性偏见。 T-20组试验在统计测试中未显示出此类错误(P = .297)。该研究证实,如果至少间隔20分钟使用一次,则对整个UL的WDV测量是可靠且敏感的。然而,证明了重要的和临床相关的逐项方法相互作用。提醒研究人员和临床医生在设计针对患者人群的调查时要注意该技术的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号