Osseointegration of hydroxyapatite-coated and noncoated Ti6Al4V implants in the presence of local infection: A comparative histomorphometrical study in rabbits

机译:局部感染存在下羟基磷灰石涂层和未涂层​​的Ti6Al4V植入物的骨整合:在兔中比较组织形态计量学研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A study was designed to investigate the osseointegration of titanium implants, either noncoated or coated with hydroxyapatite (HA), into rabbit tibiae in the presence of local infection compared with osseointegration in the absence of local infection. HA-coated or noncoated Ti cylinders were implanted into both tibiae of 32 rabbits (New Zealand Whites). Before implantation the left tibia was contaminated with different quantities of Staphylococcus aureus (10~2-10~5 CFU). Four weeks after surgery the tibiae were explanted and prepared for microbiological and histomorphometrical examination. Histomorphometrical data, as a representation of implant fixation, were obtained by measuring the percentage of bone around the implants (within a radius of 1 mm from the outer diameter of the implants) and the percentage of the circumference of the implant that was in direct contact with bone. Histomorphometry revealed, in particular for the HA implants, a relationship between the inoculum concentration and/or the presence or absence of infection with the bone contact at the distal implant side. This confirms a relationship between peri-implant infection and bone contact or remodeling. HA-coated implants developed, in the presence of bacteria, more easily a more severe infection than noncoated Ti implants, and we show in the present study that local infection will influence histomorphometrical parameters (bone-implant contact) that determine implant fixation. Precautions to prevent contamination (asepsis) and/or infection (perioperative antibiotics) are even more important for the highly biocompatible HA-coated implant.
机译:设计了一项研究,以研究在没有局部感染的情况下,钛涂层植入物在没有局部感染的情况下与兔骨胫骨的骨整合情况,无论是无涂层的还是羟基磷灰石(HA)涂层。将HA涂层或未涂层的Ti圆柱体植入32只兔子的胫骨中(新西兰白人)。植入前左胫骨被不同数量的金黄色葡萄球菌(10〜2-10〜5 CFU)污染。手术后四周,胫骨被植入并准备进行微生物学和组织形态学检查。通过测量植入物周围骨的百分比(距植入物外径1 mm以内)和直接接触的植入物周长百分比,获得组织形态计量学数据,作为植入物固定的代表。与骨头。组织形态计量学揭示,特别是对于HA植入物,接种物浓度和/或在远端植入物侧的骨接触是否存在感染之间存在关系。这证实了植入物周围感染与骨接触或重塑之间的关系。在没有细菌存在的情况下,HA涂层植入物比无涂层的Ti植入物更容易发展为更严重的感染,并且在本研究中我们表明,局部感染将影响决定植入物固定的组织形态学参数(骨骼与种植体的接触)。对于高度生物相容的HA涂层植入物,预防污染(asepsis)和/或感染(围手术期抗生素)的预防措施甚至更为重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号