Calibration and application of an intra-articular force transducer for the measurement of patellar tendon graft forces: an in situ evaluation

机译:关节内力传感器在pa骨肌腱移植力测量中的标定和应用:原位评估

获取原文
获取原文并翻译 | 示例
       

摘要

The objective of this study was to evaluate two calibration methods for the "Arthroscopically Implantable Force Probe" (AIFP) that are potentially suitable for in vivo use: (1) a direct, experimentally based method performed by applying a tensileload directly to the graft after it is harvested but prior to implantation (the "pre-implantation" technique), and (2) an indirect method that utilizes cadaver-based analytical expressions to transform the AIFP output versus anterior shear loadrelationship, which may be established in vivo, to resultant graft load (the "post-implantation" technique). The AIFP outputs during anterior shear loading of the knee joint using these two calibration methods were compared directly to graft forcemeasurements using a ligament cutting protocol and a 6 DOF load cell. The mean percent error ((actual - measured)/(actual) * 100) associated with the pre-implantation calibration ranged between 85 and 175 percent, and was dependent on the knee flexionangle tested. The percent error associated with the post-implantation technique was evaluated in two load ranges: loads less than 40 N, and loads greater than 40 N. For graft force values greater than 40 N, the mean percent errors inherent to thepost-implantation calibration method ranged between 20 and 29 percent, depending on the knee flexion angle tested. Below 40 N, these errors were substantially greater. Of the two calibration methods evaluated, the post-implantation approach provided abetter estimate of the ACL graft force than the pre-implantation technique. However, the errors for the post-implantation approach were still high and suggested that caution should be employed when using implantable force probes for in vivo measurement of ACL graft forces.
机译:这项研究的目的是评估两种可能适用于体内使用的“关节镜植入力探针”(AIFP)的校准方法:(1)一种直接的,基于实验的方法,是在移植后直接向移植物施加拉伸载荷(2)一种间接方法,该方法利用基于尸体的分析表达式将AIFP输出与可能在体内建立的前剪切载荷的关系转换为结果,从而将其收获,但是在植入之前(“植入前”技术)移植物负荷(“植入后”技术)。使用这两种校准方法在膝关节前剪切负荷期间将AIFP输出与使用韧带切割方案和6 DOF称重传感器的移植物力测量结果直接进行比较。与植入前校准相关的平均误差百分比((实际-测量)/(实际)* 100)在85%至175%之间,并且取决于所测试的膝盖屈曲角度。在两个负载范围内评估了与植入后技术相关的百分比误差:小于40 N的负载和大于40 N的负载。对于大于40 N的移植物力值,植入后校准方法固有的平均百分比误差范围在20%到29%之间,具体取决于测试的膝盖屈曲角度。低于40 N,这些误差会更大。在评估的两种校准方法中,植入后方法比植入前技术对ACL移植力的估计更好。但是,植入后方法的误差仍然很高,建议在使用植入式力探头进行ACL移植物力的体内测量时应谨慎。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号