...
首页> 外文期刊>The journal of asthma >Accuracy of the Piko-1 pocket spirometer
【24h】

Accuracy of the Piko-1 pocket spirometer

机译:Piko-1袖珍肺活量计的准确性

获取原文
获取原文并翻译 | 示例

摘要

Background. Good asthma control is the main goal of long-term asthma treatment. According to the Global Initiative for Asthma (GINA) guidelines (www.ginasthma.com), medical professionals assess asthma control based on specific questions regarding asthma symptoms and by spirometry measuring forced expiratory volume in 1 second (FEV1). Patients trained in early self-detection of asthma exacerbations use a symptom-based questionnaire, such as the Asthma Control Test (ACT) [Nathan RA, Sorkness CA, Kosinski M, et al. Development of the Asthma Control Test. A survey for assessing asthma control. J Allergy Clin Immunol 2004; 113:5964]. However, some patients may prefer harder indicators, like peak flow values, when considering how to act within their regular asthma self-management plan. Objectives. Monitoring of FEV1 at home could be an even more valuable alternative to recording peak flow values. The inexpensive handheld pocket spirometer "Piko-1?" offers the opportunity to monitor and store consecutive FEV1 values. This study assesses the accuracy of the Piko-1 device. Methods. Twenty volunteers tested 20 Piko-1 devices over five consecutive days. All results were compared to daily FEV1 values, as measured by a calibrated reference spirometer. Results. Overall, the accuracy was acceptable, although Piko-1 tended to underestimate FEV1 in the lower range. Moreover, there was no evidence of major heterogeneity between Piko-1 devices. Conclusion. The Piko-1 FEV1 measurements are sufficiently accurate to start a clinical trial to compare the detection of asthma exacerbations with this device and based on asthma symptoms alone.
机译:背景。良好的哮喘控制是长期哮喘治疗的主要目标。根据全球哮喘倡议(GINA)指南(www.ginasthma.com),医学专业人员根据有关哮喘症状的特定问题并通过肺活量测定法在1秒钟内测量强迫呼气量(FEV1)来评估哮喘控制。受过哮喘急性发作的早期自我检测训练的患者使用基于症状的问卷,例如哮喘控制测试(ACT)[Nathan RA,Sorkness CA,Kosinski M等。哮喘控制测试的发展。评估哮喘控制的调查。过敏临床免疫杂志2004; 113:5964]。但是,某些患者在考虑如何在常规哮喘自我管理计划中采取行动时,可能更喜欢较硬的指标,例如峰值流量值。目标。与记录峰值流量值相比,在家中监视FEV1可能是更有价值的选择。廉价的手持式肺部肺活量计“ Piko-1?”提供了监视和存储连续FEV1值的机会。这项研究评估了Piko-1设备的准确性。方法。二十名志愿者连续五天测试了20台Piko-1设备。将所有结果与通过校准参考肺活量计测量的每日FEV1值进行比较。结果。总体而言,尽管Piko-1倾向于在较低范围内低估FEV1,但其准确性还是可以接受的。而且,没有证据表明Piko-1设备之间存在重大异质性。结论。 Piko-1 FEV1测量值足够准确,可以启动一项临床试验,以比较仅使用哮喘症状和使用该设备对哮喘发作的检测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号