Legipid (R) Legionella Fast Detection is a test based on combined magnetic,immunocapture and enzyme-immunoassay (CEIA) for the detection of Legionella in water. The test is based on the use of anti-Legionella antibodies immobilized on magnetic microspheres. Target microorganism is preconcentrated by filtration Immunomagnetic analysis is applied on these preconcentrated water samples in a final test portion of 9 mL. The test kit was certified by the AOAC Research Institute as Performance Tested Methodsm (PTM) No. 111101 in a PTM validation which certifies the performance claims of the test method in comparison to the ISO reference method 11731-1998 and the revision 11731-2004 "Water Quality: Detection and Enumeration of Legionella pneumophila" in potable water, industrial water, and waste water. The modification of this test kit has been approved. The modification includes increasing the target analyte from L. pneumophila to Legionella species and adding an optical reader to the test method. In this study, 71 strains of Legionella spp. other than L. pneumophila were tested to determine its reactivity with the kit based on CEIA. All the strains of Legionella spp. tested by the CEIA test were confirmed positive by reference standard method ISO 11731. This test (PTM 111101) has been modified to include a final optical reading. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method. Two water matrixes were analyzed. Results show no statistically detectable difference between the test method and the reference culture method for the enumeration of Legionella spp. The relative level of detection was 93 CFU/volume examined (LOD50). For optical reading, the LOD was 40 CFU/ volume examined and the LOQ was 60 CFU/volume examined. Results showed that the test Legipid Legionella Fast Detection is equivalent to the reference culture method for the enumeration of Legionella spp
机译:Legipid(R)军团菌快速检测是一种基于磁,免疫捕获和酶联免疫分析(CEIA)的检测方法,用于检测水中的军团菌。该测试基于使用固定在磁性微球上的抗军团菌抗体。通过过滤对目标微生物进行预浓缩在这些最终浓缩的水样品中,以9 mL的最终测试量进行免疫磁分析。该测试套件已通过AOAC研究所的认证为性能测试方法(PTM)No. 111101,通过PTM验证,与ISO参考方法11731-1998和修订版11731-2004相比,可证明该测试方法的性能要求。水质:饮用水,工业用水和废水中“肺炎军团菌的检测和计数”。该测试套件的修改已获批准。修改包括将目标分析物从嗜肺乳杆菌增加到军团菌种,并将光学阅读器添加到测试方法中。在这项研究中,有71株军团菌。测试了非嗜肺乳杆菌以外的试剂盒,以测定其与基于CEIA的试剂盒的反应性。军团菌的所有菌株。通过CEIA测试获得的测试结果已通过参考标准方法ISO 11731确认为阳性。此测试(PTM 111101)已修改为包括最终光学读数。进行了方法比较研究,以证明这种修饰与参考培养方法相当。分析了两种水基质。结果表明,军团菌属物种计数的检测方法与参考培养方法之间没有统计学上可检测的差异。相对检测水平为93 CFU /检查体积(LOD50)。对于光学读取,LOD为40 CFU /体积,LOQ为60 CFU /体积。结果表明,测试的Legipid军团菌快速检测方法等同于Legionella spp计数的参考培养方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号