The pressure drop per unit depth (Delta P Pa/m) across seven potential minimum-cost biofilter media was determined at different moisture contents for superficial air velocities (u) between 0.03 and 0.13 m/s in pilot scale biofilters, and fitted to the equation Delta P = au(b) where a and b are constants. Mean values of a ranged from around 200, for pure heather, to around 6000 for a peat-heather mixture. Mean values of b ranged from 1.20, for coir, to 1.69 for softwood chips of over 75 mm screen size.
机译:对于中试规模生物滤池中表观空气流速(u)在0.03至0.13 m / s之间的表观风速(u),在不同的水分含量下,确定了七个潜在的最低成本生物滤池中每单位深度的压降(Delta P Pa / m)。方程Delta P = au(b)其中a和b是常数。平均值的范围从纯石南花的200左右到泥炭-石楠混合物的6000左右。 b的平均值从椰壳的1.20到筛分尺寸超过75毫米的软木片的1.69不等。