A high-throughput method has been developed for determining Lewisite [dichloro(2-chlorovinyl)arsine] exposure by measuring the urine metabolite 2-chlorovinylarsonous acid (CVAA) and the oxidized metabolite 2-chlorovinylarsonic acid (CVAOA). The rapid sample preparation included a simple dilution of 400 microL of urine with 40 microL of water and 1 mL of buffer containing an internal standard and brief centrifugation prior to analysis by high-performance liquid chromatography-inductively coupled plasma-mass spectrometry (ICP-MS). CVAOA and CVAA were eluted isocratically with retention factors of approximately 3.0 and 4.2, respectively, from a reversed-phase polar embedded column with a cycle time of 5 min per sample. The dynamic reaction cell, typically used to remove polyatomic isobaric interferences, was not required for ICP-MS analysis because of the resolution of chloride from arsenical peaks of interest. This method was used to detect CVAA and CVAOA in the urine of a rat administered Lewisite up to 24 h after exposure. The method demonstrated linearity over at least three orders of magnitude and had a method detection limit of 1.3 microg/L as CVAA (1.4 microg/L CVAOA). The relative standard deviations for quality control samples ranged from 3 to 6%. The method was sensitive and selective with no false positives in 100 different urine samples collected from individuals with no known exposure to Lewisite. Ninety-six samples could be analyzed in an 8-h day.
机译:已经开发出一种高通量方法,用于通过测量尿液代谢物2-氯乙烯基扁豆酸(CVAA)和氧化代谢物2-氯乙烯基扁桃酸(CVAOA)来确定路易斯石[dichloro(2-chlorovinyl)arsine]暴露。快速样品制备包括用40微升水和1毫升含有内标物的缓冲液简单稀释400微升尿液,并在通过高效液相色谱-电感耦合等离子体质谱(ICP-MS)分析之前进行短暂离心)。从反相极性嵌入式色谱柱中,分别用约3.0和4.2的保留因子等度洗脱CVAOA和CVAA,每个样品的循环时间为5分钟。 ICP-MS分析不需要动态反应池(通常用于去除多原子等压干扰物),因为可以从目标砷峰中分离出氯化物。该方法用于在暴露后长达24 h的老鼠体内注射Lewisite时检测其尿中的CVAA和CVAOA。该方法在至少三个数量级上显示出线性,并且方法检测限为CVAA(1.3 microg / L CVAOA)为1.3 microg / L。质量控制样品的相对标准偏差为3%至6%。该方法灵敏且选择性强,在从未暴露于Lewisite的个体收集的100个不同尿液样本中没有假阳性。可以在8小时内分析96个样品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号