...
首页> 外文期刊>Circulation journal >Accuracy and efficiency of left ventricular ejection fraction analysis, using multidetector row computed tomography: effect of image reconstruction window within cardiac phase, slice thickness, and interval of short-axis sections.
【24h】

Accuracy and efficiency of left ventricular ejection fraction analysis, using multidetector row computed tomography: effect of image reconstruction window within cardiac phase, slice thickness, and interval of short-axis sections.

机译:左心室射血分数分析的准确性和效率,使用多探测器行计算机断层扫描:心脏相位,切片厚度和短轴区间的图像重建窗口的影响。

获取原文
获取原文并翻译 | 示例

摘要

BACKGROUND: The aim of the present study was to assess the accuracy and efficiency of left ventricular ejection fraction (LVEF) analysis by multidetector row computed tomography (CT). METHODS AND RESULTS: The CT data of 21 patients were analyzed by semi-automated software on a workstation. In analysis of LVEF using systolic volumes in the 6 phases (30-55%), systolic images of 10% interval (35, 45, 55%) were underestimated with a mean measurement error of -0.4% and the standard error of the estimate (SEE) of 0.6%, compared with the LVEF using images of 5% interval. In analysis of LVEF using 3-slice thicknesses of axial images (1, 2, and 3 mm), and 3-slice numbers of short-axis sections (10 14, and 30 slices), there was no significant difference between the SEE of the intraobserver reproducibility and that of the analysis with 30 short-axis sections using axial images of 1-, 2- and 3-mm thickness, and that with 14 short-axis sections using axial images of 1- and 2-mm thickness. The mean analysis times were 96.9 s, 119.8 s, and 227.0 s for the analysis with 10, 14, and 30 short-axis sections, respectively. CONCLUSION: The proper selection of the reconstruction interval in the cardiac phase, the slice thickness of the axial images, and the number of short-axis sections reduces the analysis time, maintaining the accuracy of LVEF analysis. This will be acceptable for practical use at present, although more accurate analysis is preferable.
机译:背景:本研究的目的是通过多排螺旋计算机断层扫描(CT)评估左心室射血分数(LVEF)分析的准确性和效率。方法和结果:在工作站上通过半自动化软件分析了21例患者的CT数据。在6个阶段(30-55%)的收缩期容积分析LVEF中,10%间隔(35、45、55%)的收缩期影像被低估了,平均测量误差为-0.4%,估计的标准误差(SEE)为0.6%,与使用5%间隔图像的LVEF相比。在使用轴向图像的3层厚度(1、2和3 mm)和短轴截面的3层数(10 14和30层)分析LVEF时,SEE的SEE之间没有显着差异观察者的可重复性以及使用1-,2-和3-mm厚度的轴向图像对30个短轴截面的分析,以及使用1-mm和2-mm厚度的轴向图像对14个短轴截面的分析的重复性。使用10个,14个和30个短轴截面进行分析的平均分析时间分别为96.9 s,119.8 s和227.0 s。结论:正确选择心脏相位的重建间隔,轴向图像的切片厚度以及短轴截面的数量可以缩短分析时间,从而保持LVEF分析的准确性。尽管更精确的分析是可取的,但是这对于目前的实际使用是可以接受的。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号