首页> 外文期刊>CINDE Journal >Methods for Evaluation of Accuracy with Multiple Essential Parameters for Eddy Current Measurement of Pressure Tube to Calandria Tube Gap in CANDU? Reactors
【24h】

Methods for Evaluation of Accuracy with Multiple Essential Parameters for Eddy Current Measurement of Pressure Tube to Calandria Tube Gap in CANDU? Reactors

机译:用多基本参数评估精度的方法,用于在CANDU中测量压力管至Calandria管间隙的涡流。电抗器

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of inspection qualification of a particular inspection system is to show that it meets applicable inspection specification requirements. Often a requirement of the inspection system is that it meets a particular accuracy. In the case of a system with multiple inputs accompanied by additional influential parameters, calculation of the system's output accuracy can be formidable. Measurement of pressure-tube to calandria tube gap in CANDU? reactors using an eddy current based technique is presented as a particular example of a system where multiple essential parameters combine to generate a final uncertainty for the inspection system. This paper outlines two possible methods of calculating such a system's accuracy, and discusses the advantages and disadvantages of each.
机译:特定检查系统的检查资格的目的是表明其符合适用的检查规范要求。通常,检查系统的要求是满足特定的精度。如果系统具有多个输入并附带其他有影响力的参数,则系统输出精度的计算可能会非常艰巨。在CANDU中测量压力管与加热管之间的间隙?作为一个系统的特定示例,介绍了使用基于涡流技术的反应堆,其中多个基本参数组合在一起,从而为检查系统生成最终不确定性。本文概述了两种计算这种系统精度的可能方法,并讨论了每种方法的优缺点。