Effect of electric potential and current on mandibular linear measurements in cone beam CT

机译:电位和电流对锥形束CT下颌骨线性测量的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: The purpose of this study was to compare mandibular linear distances measured from cone beam CT (CBCT) images produced by different radiographic parameter settings (peak kilovoltage and milliampere value). Methods: 20 cadaver hemimandibles with edentulous ridges posterior to the mental foramen were embedded in clear resin blocks and scanned by a CBCT machine (CB MercuRayTM; Hitachi Medico Technology Corp., Chiba-ken, Japan). The radiographic parameters comprised four peak kilovoltage settings (60 kVp, 80 kVp, 100 kVp and 120 kVp) and two milliampere settings (10mA and 15 mA). A 102.4mm field of view was chosen. Each hemimandible was scanned 8 times with 8 different parameter combinations resulting in 160 CBCT data sets. On the cross-sectional images, six linear distances were measured. To assess the intraobserver variation, the 160 data sets were remeasured after 2 weeks. The measurement precision was calculated using Dahlberg's formula. With the same peak kilovoltage, the measurements yielded by different milliampere values were compared using the paired t-test. With the same milliampere value, the measurements yielded by different peak kilovoltage were compared using analysis of variance. A significant difference was considered when p<0.05. Results: Measurement precision varied from 0.03mm to 0.28 mm. No significant differences in the distances were found among the different radiographic parameter combinations. Conclusions: Based upon the specific machine in the present study, low peak kilovoltage and milliampere value might be used for linear measurements in the posterior mandible.
机译:目的:本研究的目的是比较由不同射线照相参数设置(峰值千伏电压和毫安值)产生的锥束CT(CBCT)图像测量的下颌线性距离。方法:将20具在脑孔后方有无齿ridge的尸体半透明体埋入透明的树脂块中,并用CBCT机器(CB MercuRayTM; Hitachi Medico Technology Corp.,Chiba-ken,Japan)进行扫描。射线照相参数包括四个峰值千伏设置(60 kVp,80 kVp,100 kVp和120 kVp)和两个毫安设置(10mA和15 mA)。选择了102.4mm的视野。使用8个不同的参数组合对每个半可扫描对象进行了8次扫描,得到了160个CBCT数据集。在横截面图像上,测量了六个线性距离。为了评估观察者内部的差异,在2周后重新测量了160个数据集。使用达尔伯格公式计算测量精度。在相同的峰值千伏电压下,使用配对t检验比较了不同毫安值产生的测量结果。在相同的毫安值下,使用方差分析比较了由不同峰值千伏电压得出的测量结果。当p <0.05时,考虑到显着差异。结果:测量精度从0.03mm到0.28 mm不等。在不同的射线照相参数组合之间没有发现距离的显着差异。结论:根据本研究中的特定机器,低峰值千伏电压和毫安值可用于后下颌骨的线性测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号