首页> 外文期刊>DentoMaxilloFacial Radiology >A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions.
【24h】

A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions.

机译:多检测器计算机断层扫描和锥束计算机断层扫描在评估种植牙部位尺寸方面的准确性和可靠性的比较研究。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVES: The aim of this study was to investigate the accuracy and reliability of linear measurements of edentulous ridges recorded from 16-row multidetector CT (MDCT) images and cone beam CT (CBCT) images acquired using a flat panel detector (FPD) with a large field of view (FOV), both independently and in comparison with each other. METHODS: Edentulous areas of human dry skulls were marked with gutta-percha markers to standardize the plane of the transverse cross-sections and path of measurements. The skulls were imaged using a 16-row MDCT scanner and a CBCT device with a large FOV and a FPD. Ridge dimensions were recorded from reformatted sections by two observers and compared with measurements recorded directly from the bone. The measurement errors and intra and interexaminer reliability were calculated for each modality and compared with each other. RESULTS: The overall mean of the absolute errors was 0.75 mm for MDCT and 0.49 mm for CBCT. The mean of the CBCT absolute errors was smaller than that of the MDCT absolute errors for the overall data, as well as for the site-specific data. The intraexaminer reliability score was 0.994 for MDCT and 0.995 for CBCT. The interexaminer reliability was 0.985 for MDCT and 0.958 for CBCT. CONCLUSIONS: Both MDCT and CBCT were associated with a clinically and statistically significant measurement error. CBCT measurements were significantly more accurate than those of MDCT. The measurements recorded from both modalities had a high inter and intraexaminer reliability. Accuracy of measurements was found to be more operator dependent with CBCT than with MDCT.
机译:目的:本研究的目的是调查使用平板探测器(FPD)和16排多探测器CT(MDCT)图像和锥束CT(CBCT)图像记录的无牙线性测量的准确性和可靠性。大视场(FOV),既独立又相互比较。方法:人类干颅骨的牙周部位用牙龈胶标记物进行标记,以标准化横切面和测量路径。使用16行MDCT扫描仪和具有大FOV和FPD的CBCT设备对头骨成像。两名观察者从重新格式化的剖面记录了脊的尺寸,并将其与直接从骨骼记录的测量值进行了比较。计算每种模式的测量误差以及内部和内部检查者的可靠性,并将其相互比较。结果:MDCT的绝对误差总体平均值为0.75 mm,CBCT的绝对误差平均值为0.49 mm。对于整体数据以及针对特定地点的数据,CBCT绝对误差的平均值小于MDCT绝对误差的平均值。 MDCT和CBCT的检查者内信度评分为0.994和0.995。相互检查者的可靠性对于MDCT为0.985,对于CBCT为0.958。结论:MDCT和CBCT均与临床和统计学上显着的测量误差有关。 CBCT测量比MDCT的测量准确得多。从这两种方式记录的测量结果均具有较高的内部和内部检查者可靠性。发现测量精度与CCT相比对MDCT的依赖性更大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号