BACKGROUND AND OBJECTIVES: Extent of shape change (ESC) and hypotonic shock response (HSR) have been widely used to characterize the in vitro function of platelets and have been shown to correlate with in vivo viability. These assays have been routinely performed using platelet-poor plasma (PPP) as the test sample diluent. Because of the increasing popularity of storing platelets in synthetic media, it is important to understand the effects of using these synthetic media as test diluents for ESC and HSR measurements. The objective of this study was to determine the effect of using platelet storage solutions vs. plasma for the in vitro testing of ESC and HSR. MATERIALS AND METHODS: Six laboratories participated in this study. Platelets were prepared by apheresis, the platelet-rich plasma (PRP) method, or derived from buffy-coats. Each platelet preparation was divided, half being stored in plasma and the other half in storage solution. ESC and HSR testing were performed in duplicate on days 1 and 5, using each of three diluents: autologous plasma; fresh-frozen plasma; or storage solution. RESULTS: For both ESC and HSR, dilutions made in each of the three diluents yielded significantly different results. Dilutions made in storage solutions were more than 30% lower for ESC and HSR than those made in autologous plasma (P < 0.0001). Dilutions made in thawed fresh-frozen plasma were more than 16% lower for ESC and HSR than those made in liquid autologous plasma (P < 0.0005). CONCLUSIONS: ESC and HSR test results are significantly affected by the test diluent. Platelets should be diluted in plasma (preferably autologous) for the in vitro testing of ESC and HSR, regardless of the media in which they are stored.
机译:背景与目的:形状变化(ESC)和低渗性休克反应(HSR)的程度已广泛用于表征血小板的体外功能,并已显示出与体内生存能力相关。这些测定通常使用贫血小板血浆(PPP)作为测试样品稀释剂进行。由于在合成培养基中存储血小板的日益普及,了解使用这些合成培养基作为ESC和HSR测量稀释剂的效果非常重要。这项研究的目的是确定使用血小板储存溶液与血浆进行体外ESC和HSR测试的效果。材料与方法:六个实验室参加了这项研究。通过单采血液分离术,富血小板血浆(PRP)方法制备血小板,或衍生自血沉棕黄层。将每种血小板制品分开,一半储存在血浆中,另一半储存在储存液中。 ESC和HSR测试在第1天和第5天使用三种稀释剂中的每一种重复进行:新鲜冷冻血浆或存储解决方案。结果:对于ESC和HSR,在三种稀释剂中每种稀释剂产生的结果均显着不同。与自体血浆相比,ESC和HSR在储存溶液中的稀释度要低30%以上(P <0.0001)。在融化的新鲜冷冻血浆中进行的稀释,对于ESC和HSR而言比在液体自体血浆中进行的稀释要低16%以上(P <0.0005)。结论:ESC和HSR测试结果受测试稀释剂的影响很大。血小板应稀释在血浆中(最好是自体的),以进行ESC和HSR的体外测试,而与储存血小板的介质无关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号