...
首页> 外文期刊>Vox Sanguinis: International Journal of Blood Transfusion and Immunohaematology >Increase of blood donation speed by optimizing the needle-to-tubing connection: an application of donation software.
【24h】

Increase of blood donation speed by optimizing the needle-to-tubing connection: an application of donation software.

机译:通过优化针-管连接提高献血速度:献血软件的一种应用。

获取原文
获取原文并翻译 | 示例

摘要

BACKGROUND: The speed of blood donation is affected by the resistance induced by the needle and tubing during collection. To increase blood donation speed, the connection between the needle and the tubing was modified. The aim was to evaluate the effect of this modification on various donation parameters. METHODS: Apart from the modified needle inset, the study systems were identical to reference bag systems routinely used in our centre, and only identifiable by their unique lot number. Blood collections were done at fixed sites under similar conditions using automated mixers. In total 8541 evaluable donations were performed in the reference group and 7430 in the study group. Electronically stored donation data were obtained from the mixers and used for analysis. RESULTS: The average donation speed increased from 63 +/- 12 in the reference group to 75 +/- 15 ml/min in the study group (P < 0.001), resulting in donation times of 8.10 +/- 1.52 and 6.95 +/- 1.48 min, respectively (P < 0.001). The number of units with a donation time greater than 12 min (which cannot be used for platelet production) halved in the study group. The percentage of donations with one or more donation alarms reduced from 22.2% in the reference group to 15.3% in the study group (P < 0.001). The number of adverse events (not feeling well, fainting) during donation did not increase. CONCLUSIONS: The modification of the needle inset resulted in a 19% increase in donation speed, more units could be used for platelet production, and fewer flow alarms were encountered, while the number of adverse donor events remained unchanged.
机译:背景:献血速度受采集过程中针头和导管引起的阻力影响。为了提高献血速度,修改了针头和导管之间的连接。目的是评估此修改对各种捐赠参数的影响。方法:除了改进的针头插页外,研究系统与我们中心常规使用的参考袋系统相同,并且只能通过其唯一批号进行识别。使用自动混合器在相似条件下的固定位置进行采血。参照组总共进行了8541次可评估的捐赠,研究组进行了7430次。从混合器获得电子存储的捐赠数据并用于分析。结果:平均捐赠速度从参考组的63 +/- 12增加到研究组的75 +/- 15 ml / min(P <0.001),导致捐赠时间分别为8.10 +/- 1.52和6.95 + / -分别为1.48分钟(P <0.001)。在研究组中,捐赠时间大于12分钟(不能用于血小板生产)的单位数量减少了一半。具有一个或多个捐赠警报的捐赠百分比从参考组的22.2%降至研究组的15.3%(P <0.001)。捐赠期间的不良事件(不适,昏厥)的数量没有增加。结论:针头插入的修改导致捐赠速度提高了19%,可用于生产血小板的单位更多,遇到的流量警报更少,而不良的捐赠者事件数量保持不变。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号