We present new high precision Os isotope data obtained by solution-mode MC-ICP-MS for 4 different Os isotope reference materials and compare the data to that obtained by the N-TIMS method. Mass fractionation effects for MC-ICP-MS are evaluated and we demonstrate excellent adherence to the exponential law. An improved and robust method for the derivation of interfering element isotope ratios is presented and evaluated via analysis of solutions with widely varying interfering element/analyte ratios. We show experiments that illustrate the extent of memory with a conventional solution introduction system and establish a protocol that reduces washout time and memory effects to the same level as those common for other elements typically analysed at high precision by MC-ICP-MS. Data for 4 Os Reference material solutions show excellent agreement between MC-ICP-MS and N-TIMS for all Os isotope ratios except Os-186/Os-188 and Os-184/Os-188 which are consistently lower by similar to 100 ppm and 3-5%. respectively for MC-ICP-MS. These differences are highly unlikely to arise from problems relating to Faraday cup or amplifier efficiency variations, residual mass fractionation effects or inaccuracies in the applied W interference corrections on Os-186 and Os-184 for MC-ICP-MS analyses. These issues require further investigation if the Pt-Os system is to find routine application as a geochemical tracer.
机译:我们介绍了通过溶液模式MC-ICP-MS获得的4种不同Os同位素参比材料的新高精度Os同位素数据,并将该数据与通过N-TIMS方法获得的数据进行了比较。对MC-ICP-MS的质量分离效果进行了评估,我们证明了对指数定律的出色遵循。通过对干扰元素/分析物比率变化很大的溶液的分析,提出了一种改进的鲁棒方法来推导干扰元素同位素比。我们展示了一些实验,这些实验说明了使用常规解决方案引入系统的内存范围,并建立了一个协议,该协议可以将冲洗时间和内存效果降低到与通常由MC-ICP-MS高精度分析的其他元素相同的水平。 4种Os的参考材料解决方案的数据显示,除了Os-186 / Os-188和Os-184 / Os-188外,所有Os同位素比率在MC-ICP-MS和N-TIMS之间均具有出色的一致性和3-5%。分别用于MC-ICP-MS。这些差异极不可能是由与法拉第杯或放大器效率变化,残留质量分数效应或对MC-ICP-MS分析在Os-186和Os-184上应用的W干扰校正不准确有关的问题引起的。如果要找到Pt-Os系统作为地球化学示踪剂的常规应用,则需要进一步研究这些问题。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号