首页> 外文期刊>HSS journal: the musculoskeletal journal of Hospital for Special Surgery >Minimum Distraction Gap: How Much Ankle Joint Space Is Enough in Ankle Distraction Arthroplasty?
【24h】

Minimum Distraction Gap: How Much Ankle Joint Space Is Enough in Ankle Distraction Arthroplasty?

机译:最小的牵引间隙:踝牵引置换术有多少踝关节空间?

获取原文
获取原文并翻译 | 示例
           

摘要

Background: The success of ankle distraction arthroplasty relies on the separation of the tibiotalar articular surfaces. Question/Purpose: The purpose of this study was to find the minimum distraction gap needed to ensure that the tibiotalar joint surfaces would not contact each other with full weight-bearing while under distraction. Methods: Circular external fixators were mounted to nine cadaver ankle specimens. Each specimen was then placed into a custom-designed load chamber. Loads of 0, 350, and 700N were applied to the specimen. Radiographic joint space was measured and joint contact pressure was monitored under each load. The external fixator was then sequentially distracted, and the radiographic joint space was measured under the three different loads. The experiment was stopped when there was no joint contact under 700N of load. The radiographic joint space was measured and the initial (undistracted) radiographic joint space was subtracted from it yielding the distraction gap. The minimum distraction gap (mDG) that would provide total unloading was calculated. Results: The average mDG was 2.4 mm (range, 1.6 to 4.0 mm) at 700N of load, 4.4 mm (range, 3.7 to 5.8 mm) at 350N of load, and 4.9 mm (range, 3.7 to 7.0 mm) at 0N of load. Conclusion: These results suggest that if the radiographic joint space of on a standing X-ray of an ankle undergoing distraction arthroplasty shows a minimum of 5.8 mm of DG, then there will be no contact between joint surfaces during full weight-bearing. Therefore, 5 mm of radiographic joint space, as recommended historically, may not be adequate to prevent contact of the articular surfaces during weight-bearing.
机译:背景:踝关节牵引置换术的成功依赖于胫距关节表面的分离。问题/目的:这项研究的目的是找到最小的牵引间隙,以确保胫骨距骨关节表面在牵引时不会相互承重。方法:将圆形外固定器安装到9具尸体脚踝标本上。然后将每个样品放入定制设计的装载室中。将0、350和700N的载荷施加到样品上。测量射线照相的关节间隙,并在每个载荷下监测关节接触压力。然后依次将外固定架撑开,并在三种不同负荷下测量射线照相关节间隙。当在700N的载荷下没有接头接触时,停止实验。测量射线照相关节间隙,并从中减去初始(未分散)的射线照相关节间隙,从而产生撑开间隙。计算了可提供总卸载量的最小牵引间隙(mDG)。结果:在700N负载下,平均mDG为2.4毫米(范围为1.6至4.0毫米);在350N负载下,平均mDG为4.4毫米(范围为3.7至5.8毫米);在0N负载下,平均mDG为4.9毫米(范围为3.7至7.0毫米)。加载。结论:这些结果表明,如果在进行牵张性关节置换术的踝关节的固定X射线上的X线照相关节间隙显示的DG最小为5.8 mm,则在完全负重期间关节表面之间将没有接触。因此,按照历史上的建议,放射线照相术的5 mm关节间隙可能不足以防止承重期间接触关节表面。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号