Clinical experience indicates that newly available portable hand-held x-ray units provide advantages compared to traditional fixed properly installed and operated x-ray units in dental radiography. However, concern that hand-held x-ray units produce higher operator doses than fixed x-ray units has caused regulatory agencies to mandate requirements for use of hand-held units that go beyond those recommended by the manufacturer and can discourage the use of this technology. To assess the need for additional requirements, a hand-held x-ray unit and a pair of manikins were used to measure the dose to a simulated operator under two conditions: exposures made according to the manufacturer's recommendations and exposures made according to manufacturer's recommendation except for the removal of the x-ray unit's protective backscatter shield. Dose to the simulated operator was determined using an array of personal dosimeters and a pair of pressurized ion chambers. The results indicate that the dose to an operator of this equipment will be less than 0.6 mSv y~(-1) if the device is used according to the manufacturer's recommendations. This suggests that doses to properly trained operators of well-designed, hand-held dental x-ray units will be below 1.0 mSv y~(-1) (2% of the annual occupational dose limit) even if additional no additional operational requirements are established by regulatory agencies. This level of annual dose is similar to those reported as typical dental personnel using fixed x-ray units and appears to satisfy the ALARA principal for this class of occupational exposures.
机译:临床经验表明,与传统的固定,正确安装和操作的牙科X射线摄影机相比,新近获得的便携式手持X射线摄影机具有优势。但是,由于担心手持式X射线设备产生的操作剂量要比固定式X射线设备高,因此监管机构强制要求使用手持设备的要求超出制造商的建议,可能会阻止使用这种设备。技术。为了评估对其他要求的需求,在以下两种情况下,使用了手持式X射线设备和一对人体模型来测量模拟操作员的剂量:根据制造商的建议进行的照射和根据制造商的建议进行的照射(除了用于卸下X射线机的反向散射防护罩。使用个人剂量计和一对加压离子室确定模拟操作员的剂量。结果表明,如果按照制造商的建议使用该设备,则向该设备的操作员的剂量将小于0.6 mSv y〜(-1)。这表明,即使没有额外的额外操作要求,对经过精心设计的手持式牙科X射线机操作人员的剂量也应低于1.0 mSv y〜(-1)(年度职业剂量限值的2%)。由监管机构建立。此年剂量水平类似于报告为使用固定X射线装置的典型牙科人员的剂量,并且似乎满足此类职业暴露的ALARA原则。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号