Radon mitigations in nine houses were conducted by installing sub-slab depressurization systems (SSDS) with two types of discharge and fan locations: Ground level discharge with the fan located in the basement or roof-discharge with the fan located in the attic. This paper presents a detailed comparative analysis of the radon reduction efficiency, condensation problems, and the cost-effectiveness of both SSDS installation scenarios in nine houses. The mitigations from both SSDS scenarios were successful in reducing radon. The results of rim-joist installations discharging above ground level with the fans located in the basement show that a sealed radon fan with proper fittings and sealed piping were able to reduce the radon to acceptable levels in a cost-effective manner.
机译:通过安装带有两种排放和风机位置的亚板减压系统(SSDS),在9座房屋中减轻了mi的危害:使用位于地下室的风机进行地平面排放或使用位于阁楼的风机进行屋顶排放。本文对9座住宅中两种SSDS安装方案的the降低效率,冷凝水问题以及成本效益进行了详细的比较分析。两种SSDS方案的缓解措施都成功地减少了ra。安装在地下室的风扇将钢圈桁架安装到地面以上的结果表明,带有适当配件的密封fitting风扇和密封管道能够以经济有效的方式将don降低到可接受的水平。