首页> 外文期刊>Heart rhythm: the official journal of the Heart Rhythm Society >Different characteristics of complex fractionated atrial electrograms in acute paroxysmal versus long-standing persistent atrial fibrillation.
【24h】

Different characteristics of complex fractionated atrial electrograms in acute paroxysmal versus long-standing persistent atrial fibrillation.

机译:急性阵发性与长期持续性心房颤动的复杂分级心电图的不同特征。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Complex fractionated atrial electrograms (CFAEs) may represent a phenomenon associated with sources of atrial fibrillation (AF) and are being used increasingly as targets of catheter ablation. However, current methods have limited efficacy for characterizing CFAEs important to substrate arrhythmogenicity and do not measure electrogram morphology. OBJECTIVE: The purpose of this study was to develop a methodology for quantifying the degree of morphologic heterogeneity in CFAE deflections, and to determine whether there are differences in this measurement between paroxysmal and persistent AF patients. METHODS: Two successive bipolar CFAEs of length 8.4 seconds each were acquired during AF from two sites each at the ostia of the four pulmonary veins (PVs) and from the anterior and posterior left atrial free wall in patients with paroxysmal AF (N = 10) and long-standing persistent AF (N = 10). Extrinsic and intrinsic features of electrogram shape were used to characterize fractionation in CFAE sequences. The extrinsic parameters were the amplitude, upslope, downslope, and width of each deflection. The intrinsic parameter was the voltage profile as characterized by the sum of absolute values. These measurements were compared to the mean interval between CFAE deflections, a standard fractionation indicator. RESULTS: The variability of intrinsic/extrinsic morphologic parameters was higher in paroxysmal than persistent AF at the left superior PV (P < or =.003), the posterior left atrial free wall, anterior left atrial free wall, left inferior PV, and right superior PV (P <.05 for most parameters), and the right inferior PV (not significant). Mean CFAE deflection intervals were longer at all locations in paroxysmal AF but were significant only at the left superior PV and posterior left atrial free wall (P <.05). Quantitative morphologic parameters were not well correlated with dominant frequency (r(2) <0.32); thus, our new measures are robust to changes in activation rate. CONCLUSION: A novel method for quantifying CFAEs, independent of activation rate, has been developed. The method demonstrates greater significance in the difference between CFAE morphology in paroxysmal and long-standing AF compared with mean interval between CFAE deflections. The differences identified suggest that CFAE morphology may evolve as AF persists.
机译:背景:复杂的心房电描记图(CFAEs)可能代表一种与心房颤动(AF)来源相关的现象,并且越来越多地被用作导管消融的靶标。然而,目前的方法用于表征对底物心律失常性重要的CFAE的功效有限,并且不能测量电描记图形态。目的:本研究的目的是开发一种量化CFAE偏斜形态异质性程度的方法,并确定阵发性和持续性AF患者在此测量方法上是否存在差异。方法:阵发性AF(N = 10)患者在房颤期间从四个肺静脉(PV)孔口的两个部位以及左前房和后房游离壁连续获得两个长度为8.4秒的连续双极CFAE。和长期持续性房颤(N = 10)。电图形状的外在和内在特征用于表征CFAE序列中的分级分离。外在参数是每个挠度的幅度,上坡度,下坡度和宽度。固有参数是电压曲线,其特征在于绝对值的总和。将这些测量结果与标准分馏指标CFAE偏转之间的平均间隔进行比较。结果:阵发性的内在/外在形态学参数的变异性高于左上PV(P <或= .003),左后房游离壁,左前房游离壁,左下PV和右房室持续性AF较高的PV(对于大多数参数,P <.05),以及正确的较低的PV(不显着)。在阵发性AF中,所有部位的平均CFAE偏转间隔均较长,但仅在左上PV和左后游离壁显着(P <.05)。定量形态学参数与优势频率没有很好的相关性(r(2)<0.32);因此,我们的新措施对激活率的变化具有鲁棒性。结论:开发了一种新的定量CFAEs的方法,该方法与活化速率无关。与CFAE偏转之间的平均间隔相比,该方法在阵发性和长期房颤的CFAE形态差异方面显示出更大的意义。确定的差异表明,CFAF形态可能会随着房颤的持续发展而演变。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号